- Hose material: Metal/ rigid plastic tube made of PCV, PP or PVDF
- Liquid type: Water/Other (fluids without solid particles or impurities)
- 0-75° (no surface freezing)
- Low speed cut-off value: 0.1m/s
- Display: 256*128, LCD
- Response time: 0.5-60s
- Accuracy: +/-2%, (+/-1% after calibration)
- Data storage period: 300ms
- Memory for data saving: EEPROM, data storage more than 10 years
- I/O power supply: M12 type aviation plug
- Output: 4-20mA
- Communication: Modbus RS485
- Option for output: OCT, alarm relay
- Power supply: 10-24VVDC
- Electrical power : <3W
- Ambient temperature : -10° to 60°C
- Cable length: 2m, PT100 sensor cable length is 9m
CN-BT (Low Temperature):
- Temperature Range: Ambient Temp. +10 °C to 350 °C
- Accuracy: Less than 0.5% F.S. (Min. 1 °C)
- Stability: ± 0.5 °C
- Resolution: 0.1 °C
- Emissivity: 0.98
- Aperture Diameter: 25 mm
- Time to Reach Max Temperature: 45 minutes
- Stabilization Time: 20 minutes (above 75 °C)
- Dimensions (L x W x H) / Weight: 485 x 430 x 190 mm / 11 kg
- Calibration Certification: Factory with ISO17025 traceability included
CN-HT (High Temperature):
- Temperature Range: 500 °C to 1200 °C
- Accuracy: Less than 0.5% F.S. (Min. 3 °C)
- Stability: ± 0.5 °C
- Resolution: 1 °C
- Emissivity: 0.98
- Aperture Diameter: 25 mm
- Time to Reach Max Temperature: 60 minutes
- Stabilization Time: 20 minutes (above 75 °C)
- Dimensions (L x W x H) / Weight: 485 x 430 x 190 mm / 11 kg
- Calibration Certification: Factory with ISO17025 traceability included
CN-BT (Low Temperature):
- Temperature Range: Ambient Temp. +10 °C to 350 °C
- Accuracy: Less than 0.5% F.S. (Min. 1 °C)
- Stability: ± 0.5 °C
- Resolution: 0.1 °C
- Emissivity: 0.98
- Aperture Diameter: 25 mm
- Time to Reach Max Temperature: 45 minutes
- Stabilization Time: 20 minutes (above 75 °C)
- Dimensions (L x W x H) / Weight: 485 x 430 x 190 mm / 11 kg
- Calibration Certification: Factory with ISO17025 traceability included
CN-DT (Duo – Dual Cavities):
- Cavity 1: +50 °C to 300 °C
- Cavity 2: +250 °C to 600 °C
- Accuracy: Less than 0.5% F.S. (Cavity 1 Min. 1 °C / Cavity 2 Min. 2 °C)
- Stability: ± 0.5 °C
- Resolution: 1 °C
- Emissivity: 0.98
- Aperture Diameter: 25 mm
- Time to Reach Max Temperature: 45 minutes
- Stabilization Time: 30 minutes (above 75 °C)
- Dimensions (L x W x H) / Weight: 450 x 410 x 190 mm / 14 kg
- Calibration Certification: Factory with ISO17025 traceability included
- Model : CTC-1200
- Working range : 300 °C to 1200 °C
- Resolution : 1 °C
- Accuracy : ± 2 °C
- Stability : ± 0.5 °C
- Stabilization time : 15 minutes
- Temperature display : °C / °F switchable
- Well diameter : 26 mm
- Immersion depth : 105 mm
- Heating time (ambient to max.) : Approximately 60 minutes
- Cooling time : Approximately 45 minutes (with forced air cooling)
- Pressostat test : Suitable
- Thermowell diameter : 8 mm
- Power supply / consumption : 230V AC, 50 Hz / 115V AC, 60 Hz - 700 W - switchable
- Instrument dimensions (L x W x H) : 160 x 365 x 450 mm
- Instrument weight : 15 Kg
Measurement capacity :
- Thermocouples : ISA Types J, K, R, S, N
- RTD : Pt100 IEC Std.
- mA : 0 to 25 mA
- mV : 0 to 100 / 1000 mV
- Volt : 0 to 10 V
- Resistance : 0 to 500Ω / 3.5 KΩ
PN:16 bar R250 T50
Power supply: 3.6V lithium battery
Lifespan ≥ 10 years
Fluid: cold water & hot water
Fluid temperature: up to 50°C
Protection: IP68
Installation: Any angle
Communication: RS485 Modbus RTU
MID and ACS approved
• Water and other clear liquids metering
• Non-intrusive measurement
• Energy metering possible as an option
• Size: DN15 to DN65
• No intervention on the pipeline
• Ultra-fast hot installation
• Pipe: PVC, carbon steel, stainless steel, copper
• Large 256*128 screen for optimal reading
• 4-20 mA output
• RS485 Modbus RTU communication
• Sleek & ultra-compact design
• IP65 aluminum alloy housing
• Excellent price-performance ratio