  • Categories: Flow
  • Categories: Pressure
  • Categories: Temperature
  • Categories: Metering
  • Categories: Calibration
  • Pressure range : 95% of vacuum up to 100 bar 
  • Media : Air
  • Adjustment resolution: 0,1 mbar
  • Material : Body: SS & aluminum ~ Ram/adapters: SS ~ Seals: Buna-N
  • Connections: 1/4NPT F, 1/4BSP F, or M20X1.5 F
  • Dimensions: Base : 315×198 ~ Height ×140 (mm) 2.6 kg
  • User-friendly, robust design and reliable performance
  • Measuring range: 200Pa-10MPa
  • Output signal: 4-20mA, 4 ~ 20mA / HART, client
  • Reference accuracy: ± 0.075% URL, optional ± 0.05% URL
  • Operating temperature: -40-85, LCD display: -40-120 ℃
  • Fluid temperature: -40-120
  • Measuring fluid: level, density and pressure of the liquid, gas or vapor
  • Protection class: IP67
  • Diaphragm material: SUS316L, Hastelloy C
  • Stability: ± 0.2% URL / 60 months
  • Process connection: M20 * 1.5 (M), 1 / 2-14NPT (F), 1 / 4-18NPT (F)
  • Approvals: ATEX, IECEx, NEPSI, RoHS, CE
  • Hose material: Metal/ rigid plastic tube made of PCV, PP or PVDF
  • Liquid type: Water/Other (fluids without solid particles or impurities)
  • 0-75° (no surface freezing)
  • Low speed cut-off value: 0.1m/s
  • Display: 256*128, LCD
  • Response time: 0.5-60s
  • Accuracy: +/-2%, (+/-1% after calibration)
  • Data storage period: 300ms
  • Memory for data saving: EEPROM, data storage more than 10 years
  • I/O power supply: M12 type aviation plug
  • Output: 4-20mA
  • Communication: Modbus RS485
  • Option for output: OCT, alarm relay 
  • Power supply: 10-24VVDC
  • Electrical power : <3W
  • Ambient temperature : -10° to 60°C
  • Cable length: 2m, PT100 sensor cable length is 9m

  • Pressure range : 95% of vacuum up to 140 bar 
  • Media : Air
  • Adjustment resolution: 0,1 mbar
  • Material : Body: SS & aluminum ~ Ram/adapters: SS ~ Seals: Buna-N
  • Connections: 1/4NPT F, 1/4BSP F, or M20X1.5 F
  • Dimensions: Base : 540×270 ~ Height ×178 (mm) 6.5 kg
  • User-friendly, robust design and reliable performance
  • Measuring range: 200Pa-10MPa
  • Output signal: 4-20mA, 4 ~ 20mA / HART, client
  • Reference accuracy: ± 0.075% URL, optional ± 0.05% URL
  • Operating temperature: -40-85, LCD display: -40-120 ℃
  • Fluid temperature: -40-120
  • Measuring fluid: level, density and pressure of the liquid, gas or vapor
  • Protection class: IP67
  • Diaphragm material: SUS316L, Hastelloy C
  • Stability: ± 0.2% URL / 60 months
  • Process connection: M20 * 1.5 (M), 1 / 2-14NPT (F), 1 / 4-18NPT (F)
  • Approvals: ATEX, MC, NEPSI, CE
  • Pressure range : 95% of vacuum up to 200 bar 
  • Media : Air
  • Adjustment resolution: 0,1 mbar
  • Material : Body: SS & aluminum ~ Ram/adapters: SS ~ Seals: Buna-N
  • Connections: 1/4NPT F, 1/4BSP F, or M20X1.5 F
  • Dimensions: Base : 540×270 ~ Height ×178 (mm) 6,5 kg
  • User-friendly, robust design and reliable performance
  • Measuring range: 10kPa-1MPa
  • Output signal: 4-20mA, 4 ~ 20mA / HART, client
  • Reference accuracy: ± 0.1% URL, optional ± 0.075% URL
  • Substrate temperature: -40-120
  • Measuring medium: pressure, level, differential pressure, density, interface, flow
  • Protection class: IP67
  • Diaphragm material: SUS316L, Hastelloy C
  • Stability: ± 0.2% URL / 5 years
  • Process connection: DN50PN10, DN80PN10, DN100PN10
  • Approvals: CE, EX- certificate of proof
  • Pressure range : 85% of vacuum up to 400 bar 
  • Media : Oil and Water
  • Material : Body: SS & aluminum ~ Ram/adapters: SS ~ Seals: Buna-N
  • Connections: 1/4NPT F, 1/4BSP F, or M20X1.5 F
  • Dimensions: Base : 240×140 ~ Height ×120 (mm) 1,7kg
  • User-friendly, robust design and reliable performance
  • Measuring range: 200Pa-40MPa
  • Output signal: 4-20mA, 4 ~ 20mA / HART, client
  • Reference accuracy: ± 0.075% URL, optional ± 0.05% URL
  • Fluid temperature: -40-120
  • Measuring fluid: level, density and pressure of the liquid, gas or vapor
  • Protection class: IP67
  • Diaphragm material: SUS316L, Hastelloy C
  • Stability: ± 0.2% URL / 60 months
  • Process connection: M20 * 1.5 (M), 1 / 2-14NPT (F), 1 / 4-18NPT (F)
  • Approvals: ATEX, MC, NEPSI,, CE
  • Pressure range : 85% of vacuum up to 700 bar 
  • Media : Oil and Water
  • Material : Body: SS & aluminum ~ Ram/adapters: SS ~ Seals: Buna-N
  • Connections: 1/4NPT F, 1/4BSP F, or M20X1.5 F
  • Dimensions: Base : 290×198 ~ Height ×135 (mm) 3,2kg
  • User-friendly, robust design and reliable performance
  • Measuring range: 2kPa-10MPa
  • Output signal: 4-20mA, 4 ~ 20mA / HART, client
  • Reference accuracy: ± 0.15% URL, optional ± 0.1% URL
  • Operating temperature: -40-85, LCD display: -20-70 ℃
  • Fluid temperature: -40-120
  • Measuring fluid: level, density and pressure of the liquid, gas or vapor
  • Protection class: IP67
  • Diaphragm material: SUS316L, Hastelloy C
  • Stability: ± 0.2% URL / 60 months
  • Process connection: M20 * 1.5 (M), 1 / 2-14NPT (F), 1 / 4-18NPT (F)