Theme Features - you can manage from admin

Select Theme
Custome Color 1
Custome Color 2
Box-Layout
Background Pattern

Custome background also available in admin.

Background color
Wow Animation Enable
Slider 3D Animation Enable
Menu Sticky Enable
Bottom Option Enable
Accueil
Accueil
Grid
List

There are 112 products.

Grid
List
Showing 37-48 of 112 item(s)
Active filters
  • Price: €0.00 - €1.00
Models: PPC-H + (accuracy 0.025% FS)
Pressure Range: 0 to 200 Bar.
Temperature Compensation: 0 °C to 50 °C.
Display: Backlit LCD, 5-digit resolution, multiple units (Pa, Bar, PSI, mmHg, etc.).
Inputs: Current (50 mA active / 25 mA passive), voltage (0-30 VDC), resolution 0.001.
Pressure Generation: Integrated pneumatic/hydraulic pumps with fine adjustment.
Construction: Robust IP10 case, 330 x 235 x 125 mm, 6 kg.
Overpressure Alarm: 120% FS (visual/audible).
Power Supply: Rechargeable battery.
Delivery: Calibrator, adapters, test kit, oil, RS-232, manual.
  • Measuring range: 10kPa-1MPa
  • Output signal: 4-20mA, 4 ~ 20mA / HART, client
  • Reference accuracy: ± 0.1% URL, optional ± 0.075% URL
  • Substrate temperature: -40-120
  • Measuring medium: pressure, level, differential pressure, density, interface, flow
  • Protection class: IP67
  • Diaphragm material: SUS316L, Hastelloy C
  • Stability: ± 0.2% URL / 5 years
  • Process connection: DN50PN10, DN80PN10, DN100PN10
  • Approvals: CE, EX- certificate of proof
  • Non-contact level measurement of liquids
  • Applicable for continuous level measurement of liquids aggressive liquids
    with lower demands on pressure and temperature ranges.
  • Measuring ranges : 0 ~ 30m
  • Accuracy : ± 2mm
  • Process pressure : -1 bar ~ 2 bar
  • Process temperature : -40℃ ~ +130℃
  • Media-conracting materials :
    Process fittings: PP
    Antenna: PP
    Seal: PP PTFE
  • Display and Adjustment LCD display, tank side display and tank side hub
  • Communications : HART, RS485 Modbus, 4-20 mA...
  • Protect Level : IP67
  • Ex information : EX ia IIC T6 Ga Ex d ia [iaGa] IIC T6/T2 Gb
  • Different Models depending on the application
Plage de température : 50 °C ~ 350 °C
Accuracy: ± 0.4 °C
Stability: ± 0.05 °C
Resolution: 0.1 °C
Stabilization time: 20 minutes
Temperature unit: Selectable °C or °F
Well diameter: 25 mm
Immersion length: 110 mm
Heating time: 20 minutes (ambient to 350 °C)
Cooling time: 33 minutes (350 °C to ambient temperature)
Interchangeable insert: Well for Ø 1/4’’ and 1/2’’ probes as standard (other sizes available on request).
Switch test: Provided
Power supply / Consumption: 230 V AC, 50 Hz, 520 W
Dimensions (L x W x H) / Weight: 160 x 365 x 350 mm / 9 kg
Enclosure type: Portable

Pressure range: -0.85 to 10 bar
Pressure measurement and generation
Accuracy: ± 0.05% FS
Temperature compensation: 0 °C to 50 °C
Selectable measurement units:Kg/cm², Bar, mBar, PSI, mH₂O, mmH₂O, cmH₂O, inH₂O, ftH₂O, mmHg, inHg, Atm, MPa, kPa, Pa
Current measurement: Active loop: 50 mA, Passive loop: 25 mA, Load resistance: 800 Ω
Voltage measurement: 0 to 30 VDC
Resolution (mA / V): 0.001
Switch test: Maximum 5 VDC
Medium: Air
Overpressure alarm: Visual and audible, 120% FS
Pressure generation: Integrated pneumatic pump with fine adjustment vernier and depressurization valve
Power supply: Rechargeable 7.2 V AA battery
Dimensions / Weight: 330 x 235 x 125 mm, 4 kg

Models: PPC-H (accuracy 0.05% FS)
Pressure Range: 0 to 400 Bar.
Temperature Compensation: 0 °C to 50 °C.
Display: Backlit LCD, 5-digit resolution, multiple units (Pa, Bar, PSI, mmHg, etc.).
Inputs: Current (50 mA active / 25 mA passive), voltage (0-30 VDC), resolution 0.001.
Pressure Generation: Integrated pneumatic/hydraulic pumps with fine adjustment.
Construction: Robust IP10 case, 330 x 235 x 125 mm, 6 kg.
Overpressure Alarm: 120% FS (visual/audible).
Power Supply: Rechargeable battery.
Delivery: Calibrator, adapters, test kit, oil, RS-232, manual.
  • Compact, handheld, User friendly menu
  • Easy to read Color Graphical TFT LCD display
  • Rechargeable lithium Ion battery with enhanced power control for prolonged battery life
  • Measure: mA/ V/ mV/ mA (24V)/ Switch-test / RTD/ TC/ Frequency/ Pulse
  • Source: mA/ V/ mV/ mA(2W)/ Resistance/ RTD/ TC/ Frequency/ Pulse
  • 24 VDC Loop power Supply to power transmitters and loops
  • Step/Ramp functions with Auto/Man selection
  • Universal Serial Bus (USB) communication port for charging, data retrieve and firmware upgrade
  • Data Logging to measure long time drift
  • Other Features: Max/Min/Average, filter settings, tare facility, adjustable backlight, alarm annunciation (on display and buzzer), glance screen mode
  • Continuity Test
  • Pulsed RTD transmitter compatible
  • HART loop resistor
  • Non-contact level measurement of liquids
  • Applicable for continuous level measurement of liquids
    extremely aggressiveness in storage containers, reactors or process vessels.
  • Measuring ranges : 0 ~ 30m
  • Accuracy : ± 2mm
  • Process pressure : -1 bar ~ 16 bar
  • Process temperature : -40℃ ~ +200℃
  • Media-conracting materials :
    Process fittings: 316L
    Antenna: PTFE, PFA, PP
    Seal: FKM, EPDM, KALREZ
  • Display and Adjustment LCD display, tank side display and tank side hub
  • Communications : HART, RS485 Modbus, 4-20 mA...
  • Protect Level : IP67
  • Ex information : EX ia IIC T6 Ga Ex d ia [iaGa] IIC T6/T2 Gb Ex iaD tD A21 IP67T80ºC/T290ºC
  • Different Models depending on the application
Température range : 50 °C ~ 650 °C
Accuracy: ± 0.6 °C
Stability: ± 0.05 °C
Resolution: 0.1 °C
Stabilization time: 20 minutes
Temperature unit: Selectable °C or °F
Well diameter: 25 mm
Immersion length: 110 mm
Heating time: 20 minutes (ambient to 650 °C)
Cooling time: 42 minutes (650 °C to ambient temperature)
Interchangeable insert: Well for Ø 1/4’’ and 1/2’’ probes as standard (other sizes available on request).
Switch test: Provided
Power supply / Consumption: 230 V AC, 50 Hz, 1230 W
Dimensions (L x W x H) / Weight: 160 x 365 x 350 mm / 11 kg
Enclosure type: Portable


Pressure range: -0.85 to 20 bar
Pressure measurement and generation
Accuracy: ± 0.05% FS
Temperature compensation: 0 °C to 50 °C
Selectable measurement units:Kg/cm², Bar, mBar, PSI, mH₂O, mmH₂O, cmH₂O, inH₂O, ftH₂O, mmHg, inHg, Atm, MPa, kPa, Pa
Current measurement: Active loop: 50 mA, Passive loop: 25 mA, Load resistance: 800 Ω
Voltage measurement: 0 to 30 VDC
Resolution (mA / V): 0.001
Switch test: Maximum 5 VDC
Medium: Air
Overpressure alarm: Visual and audible, 120% FS
Pressure generation: Integrated pneumatic pump with fine adjustment vernier and depressurization valve
Power supply: Rechargeable 7.2 V AA battery
Dimensions / Weight: 330 x 235 x 125 mm, 4 kg


€0.00 Price
Models: PPC-H + (accuracy 0.025% FS)
Pressure Range: 0 to 400 Bar.
Temperature Compensation: 0 °C to 50 °C.
Display: Backlit LCD, 5-digit resolution, multiple units (Pa, Bar, PSI, mmHg, etc.).
Inputs: Current (50 mA active / 25 mA passive), voltage (0-30 VDC), resolution 0.001.
Pressure Generation: Integrated pneumatic/hydraulic pumps with fine adjustment.
Construction: Robust IP10 case, 330 x 235 x 125 mm, 6 kg.
Overpressure Alarm: 120% FS (visual/audible).
Power Supply: Rechargeable battery.
Delivery: Calibrator, adapters, test kit, oil, RS-232, manual.