Theme Features - you can manage from admin

Select Theme
Custome Color 1
Custome Color 2
Box-Layout
Background Pattern

Custome background also available in admin.

Background color
Wow Animation Enable
Slider 3D Animation Enable
Menu Sticky Enable
Bottom Option Enable
Accueil
Accueil
Grid
List

There are 10 products.

Grid
List
Showing 1-10 of 10 item(s)
Active filters
  • Weight: 11kg - 17kg
  • Pressure range : 85% of vacuum up to 1000 bar 
  • Media : Oil
  • Material : Body: SS & aluminum ~ Ram/adapters: SS ~ Seals: Buna-N
  • Connections: 1/4NPT F, 1/4BSP F, or M20X1.5 F
  • Dimensions: Base : 520×360 ~ Height ×230 (mm) 16 kg
  • User-friendly, robust design and reliable performance

Température range : 50 °C ~ 650 °C
Accuracy: ± 0.3 °C
Stability: ± 0.02 °C
Resolution: 0.01 °C
Stabilization time: 7 minutes
Temperature unit: °C or °F selectable
Well diameter: 30 mm
Immersion length: 150 mm
Heating time: 10 minutes (Amb. to 120 °C)
Cooling time: 15 minutes (Amb. to (-) 10 °C)
                    25 minutes (120 °C to (-) 10 °C)
Communication port: RS232 port
Calibration software: MET-CAL as standard
Switch test: Provided
Power supply / Consumption: 110V to 240V AC, 50 to 60 Hz, 150 W
Dimensions (W x D x H) / Weight: 160 x 365 x 450 mm / 9 kg
Type of case: Portable
Carrying case: Provided
ISO17025 calibration certificate: Provided

Température range: 50 °C ~ 650 °C 300 °C ~ 1200 °C
Accuracy: ± 2 °C
Stability: ± 0.3 °C
Resolution: 0.1 °C
Stabilization time: 15 minutes
Temperature unit: Selectable °C or °F
Well diameter: 30 mm
Immersion length: 105 mm
Heating time: 30 minutes (100 °C to 800 °C)
Cooling time: 120 minutes (800 °C to 200 °C)
Communication port: Standard RS232 port
Calibration software: Standard MET-CAL software included
Switch test: Provided
Power supply / Consumption: 230V AC, 50 Hz & 115V AC switchable, 60 Hz
Dimensions (L x W x H) / Weight: 160 x 365 x 450 mm / 11 kg
Enclosure type: Portable
Carrying case: Included
ISO17025 calibration certificate: Included
Température range : 50 °C ~ 650 °C
Accuracy: ± 0.6 °C
Stability: ± 0.05 °C
Resolution: 0.1 °C
Stabilization time: 20 minutes
Temperature unit: Selectable °C or °F
Well diameter: 25 mm
Immersion length: 110 mm
Heating time: 20 minutes (ambient to 650 °C)
Cooling time: 42 minutes (650 °C to ambient temperature)
Interchangeable insert: Well for Ø 1/4’’ and 1/2’’ probes as standard (other sizes available on request).
Switch test: Provided
Power supply / Consumption: 230 V AC, 50 Hz, 1230 W
Dimensions (L x W x H) / Weight: 160 x 365 x 350 mm / 11 kg
Enclosure type: Portable

  • Temperature range: -100°C to +25°C
  • Accuracy: ± 0.3 °C
  • Stability: ± 0.05 °C
  • Resolution:Stabilization time: 15 minutes
    • 0.01°C (from +25 to +19.99°C)
    • 0.1°C (from 20°C to -100°C)
  • Temperature unit: Selectable °C or °F
  • Well diameter: 30 mm
  • Immersion length: 150 mm
  • Heating time: 50 minutes (from ambient to maximum)
  • Cooling time:Switch test: Provided
    • 40 minutes (from +25°C to -60°C)
    • 50 minutes (from -60°C to -100°C)
  • Power supply / Consumption: 90 ~ 220 V AC, 50/60 Hz
  • Dimensions (L x P x H) : 439 x 240 x 358 mm
  • Weight: 15 kg
  • Calibration certificate: Factory traceable to ISO17025 included or ISO17025 certificate from an accredited lab

CN-BT (Low Temperature):

  • Temperature Range: Ambient Temp. +10 °C to 350 °C
  • Accuracy: Less than 0.5% F.S. (Min. 1 °C)
  • Stability: ± 0.5 °C
  • Resolution: 0.1 °C
  • Emissivity: 0.98
  • Aperture Diameter: 25 mm
  • Time to Reach Max Temperature: 45 minutes
  • Stabilization Time: 20 minutes (above 75 °C)
  • Dimensions (L x W x H) / Weight: 485 x 430 x 190 mm / 11 kg
  • Calibration Certification: Factory with ISO17025 traceability included


CN-HT (High Temperature):

  • Temperature Range: 500 °C to 1200 °C
  • Accuracy: Less than 0.5% F.S. (Min. 3 °C)
  • Stability: ± 0.5 °C
  • Resolution: 1 °C
  • Emissivity: 0.98
  • Aperture Diameter: 25 mm
  • Time to Reach Max Temperature: 60 minutes
  • Stabilization Time: 20 minutes (above 75 °C)
  • Dimensions (L x W x H) / Weight: 485 x 430 x 190 mm / 11 kg
  • Calibration Certification: Factory with ISO17025 traceability included

CN-BT (Low Temperature):

  • Temperature Range: Ambient Temp. +10 °C to 350 °C
  • Accuracy: Less than 0.5% F.S. (Min. 1 °C)
  • Stability: ± 0.5 °C
  • Resolution: 0.1 °C
  • Emissivity: 0.98
  • Aperture Diameter: 25 mm
  • Time to Reach Max Temperature: 45 minutes
  • Stabilization Time: 20 minutes (above 75 °C)
  • Dimensions (L x W x H) / Weight: 485 x 430 x 190 mm / 11 kg
  • Calibration Certification: Factory with ISO17025 traceability included

CN-DT (Duo – Dual Cavities):

  • Cavity 1: +50 °C to 300 °C
  • Cavity 2: +250 °C to 600 °C
  • Accuracy: Less than 0.5% F.S. (Cavity 1 Min. 1 °C / Cavity 2 Min. 2 °C)
  • Stability: ± 0.5 °C
  • Resolution: 1 °C
  • Emissivity: 0.98
  • Aperture Diameter: 25 mm
  • Time to Reach Max Temperature: 45 minutes
  • Stabilization Time: 30 minutes (above 75 °C)
  • Dimensions (L x W x H) / Weight: 450 x 410 x 190 mm / 14 kg
  • Calibration Certification: Factory with ISO17025 traceability included

  • Model : CTC-1200
  • Working range : 300 °C to 1200 °C
  • Resolution : 1 °C
  • Accuracy : ± 2 °C
  • Stability : ± 0.5 °C
  • Stabilization time : 15 minutes
  • Temperature display : °C / °F switchable
  • Well diameter : 26 mm
  • Immersion depth : 105 mm
  • Heating time (ambient to max.) : Approximately 60 minutes
  • Cooling time : Approximately 45 minutes (with forced air cooling)
  • Pressostat test : Suitable
  • Thermowell diameter : 8 mm
  • Power supply / consumption : 230V AC, 50 Hz / 115V AC, 60 Hz - 700 W - switchable
  • Instrument dimensions (L x W x H) : 160 x 365 x 450 mm
  • Instrument weight : 15 Kg

Measurement capacity :

  • Thermocouples : ISA Types J, K, R, S, N
  • RTD : Pt100 IEC Std.
  • mA : 0 to 25 mA
  • mV : 0 to 100 / 1000 mV
  • Volt : 0 to 10 V
  • Resistance : 0 to 500Ω / 3.5 KΩ