Theme Features - you can manage from admin

Select Theme
Custome Color 1
Custome Color 2
Box-Layout
Background Pattern

Custome background also available in admin.

Background color
Wow Animation Enable
Slider 3D Animation Enable
Menu Sticky Enable
Bottom Option Enable
Accueil
Accueil
Grid
List

There are 31 products.

Grid
List
Showing 1-12 of 31 item(s)
Active filters
  • Categories: Temperature
  • Categories: LEVEL
  • Categories: Metering
  • Weight: 0kg - 0.5kg
  • Rugged weather proof enclosure with Exproof enclosure as an option
  • Available in Wall and Duct mounting versions.
  • Three variants.
  • Measuring Range: 0-100% RH in models, suitable formmany applications
  • Class-A RTD Pt 100 sensor used for temperature measurement
  • Linearised analog 4-20mA signal output (2wire loop powered)
  • Replaceable humidity sensor assembly
  • Capacitance based sensing.
  • High Accuracy
  • Excellent long-term stability
  • Universal input (RTD, Thermocouple, Ohm, mV)
  • Available in below options :
    TT7S10-D: Din Rail mount with 3″, 4 digit LED display
    TT7S10-XP: Wall or 2″ Pipe mount Ex-proof Transmitter with touch sense keys
  • 0.56″, 4 digit LED display in Single Compartment
  • 0.39″, 4 digit LED display in Dual Compartment
  • 1.5 KV RMS Isolation between Input & Output Linearized Output
  • Highly Accurate
  • Fully Programmable for Input type & Range
  • Digital Filter
  • Easy configuration using keys and display
  • Windows mTRAN software for Configuration, Calibration & Monitoring
  • Reverse Loop polarity protection
  • Direct / Reverse output
  • Sensor break detection
  • Non-contact level measurement of liquids
  • Applicable for continuous level measurement of liquids
    with slightly aggressiveness in storage containers, reactors or process vessels.
  • Measuring ranges : 0 ~ 30m
  • Accuracy : ± 2mm
  • Process pressure : -1 bar ~ 2 bar
  • Process temperature : -40℃ ~ +200℃
  • Media-conracting materials :
    Process fittings: 316L
    Antenna: PEEK PTFE
    Seal: FKM, EPDM, KALREZ
  • Display and Adjustment LCD display, tank side display and tank side hub
  • Communications : HART, RS485 Modbus, 4-20 mA...
  • Protect Level : IP67
  • Ex information : EX ia IIC T6 Ga Ex d ia [iaGa] IIC T6/T2 Gb
  • Different Models depending on the application
  • Universal input (RTD, thermocouple, Ohm, mV)
  • 1.5 KV RMS Isolation between Input & Output
  • Linearized Output
  • Highly Accurate
  • Fully Programmable for Input type & Range
  • Fast Response time: <500 ms
  • Digital Filter
  • Windows mTRAN software for Configuration, Calibration & Monitoring
  • Reverse polarity protection
  • Direct/Reverse output
  • Sensor break detection
  • Loop/Aux Powered models
  • Non-contact level measurement of liquids
  • Continuous level measurement of aggressive liquids
    (storage containers, reactors or process vessels...)
  • Measuring ranges : 0 ~ 20m or 0 ~ 30m
  • Accuracy : ± 2mm
  • Process pressure : -1 bar ~ 2 bar
  • Process temperature : -40℃ ~ +200℃
  • Media-conracting materials :
    Process fittings: PP
    Antenna: PP
    Seal: FKM, EPDM, KALREZ
  • Display and Adjustment LCD display, tank side display and tank side hub
  • Communications : HART, RS485 Modbus, 4-20 mA...
  • Protect Level : IP67
  • Ex information : EX ia IIC T6 Ga Ex d ia [iaGa] IIC T6/T2 Gb
  • Different Models depending on the application
  • Non-contact level measurement of liquids
  • Applicable for continuous level measurement of liquids aggressive liquids
    with lower demands on pressure and temperature ranges.
  • Measuring ranges : 0 ~ 30m
  • Accuracy : ± 2mm
  • Process pressure : -1 bar ~ 2 bar
  • Process temperature : -40℃ ~ +130℃
  • Media-conracting materials :
    Process fittings: PP
    Antenna: PP
    Seal: PP PTFE
  • Display and Adjustment LCD display, tank side display and tank side hub
  • Communications : HART, RS485 Modbus, 4-20 mA...
  • Protect Level : IP67
  • Ex information : EX ia IIC T6 Ga Ex d ia [iaGa] IIC T6/T2 Gb
  • Different Models depending on the application

  • Communication : e-HART
  • Output : 4 to 20mA
  • Supply voltage : 7.5 to 45VDC
  • Input : RTC, TC, Ohm, mV
  • Cold junction : Internal 
  • Accuracy (Pt100) : <0,2K or 0,08%
  • Influence of ambient : Negligible 
  • Load influence : Negligible
  • Power supply influence : Negligible 
  • Resolution : 0.3uA
  • Installation : DIN Rail 

  • Non-contact level measurement of liquids
  • Applicable for continuous level measurement of liquids
    extremely aggressiveness in storage containers, reactors or process vessels.
  • Measuring ranges : 0 ~ 30m
  • Accuracy : ± 2mm
  • Process pressure : -1 bar ~ 16 bar
  • Process temperature : -40℃ ~ +200℃
  • Media-conracting materials :
    Process fittings: 316L
    Antenna: PTFE, PFA, PP
    Seal: FKM, EPDM, KALREZ
  • Display and Adjustment LCD display, tank side display and tank side hub
  • Communications : HART, RS485 Modbus, 4-20 mA...
  • Protect Level : IP67
  • Ex information : EX ia IIC T6 Ga Ex d ia [iaGa] IIC T6/T2 Gb Ex iaD tD A21 IP67T80ºC/T290ºC
  • Different Models depending on the application

  • Communication : e-HART
  • Output : 4 to 20mA
  • Supply voltage : 7.5 to 45VDC
  • Input : RTC, TC, Ohm, mV
  • Cold junction : Internal 
  • Accuracy (Pt100) : <0,2K or 0,08%
  • Influence of ambient : Negligible 
  • Load influence : Negligible
  • Power supply influence : Negligible 
  • Resolution : 0.3uA
  • Galvanic isolation (In/Out) : 2KVAC
  • Installation : DIN Rail 

  • Communication : e-HART
  • Output : 4 to 20mA
  • Supply voltage : 7.5 to 45VDC
  • Input : RTC, TC, Ohm, mV
  • Cold junction : Internal 
  • Accuracy (Pt100) : <0,2K or 0,08%
  • Influence of ambient : Negligible 
  • Load influence : Negligible
  • Power supply influence : Negligible 
  • Resolution : 0.3uA
  • Galvanic isolation (In/Out) : 2KVAC
  • Installation : DIN Rail 

  • Universal settings with HART-protocol for various input signals
  • 2 wire technology, 4 to 20mA analogue output
  • High accuracy in total ambient temperature range
  • Galvanic isolation
  • An internal temperature sensor of active temperature compensation
  • Wide voltage supply range
  • Customer specific measurement range settings
  • Simple and user friendly software
  • Multiparametric backlight rotatable LCD display

  • Universally progammable with HART-protocol for various input signals
  • Two-wire technology, analogue output 4 to 20mA
  • Highly accurate in entire operating temperature range
  • Wide voltage supply range
  • Customer specific measurement range settings
  • Simple and user friendly software
  • Multiparametric backlight rotatable LCD display