Showing 1-12 of 48 item(s)
Active filters
  • Categories: Pressure
  • Categories: LEVEL
  • Categories: Calibration
  • Weight: 0kg - 0.5kg
  • Accuracy: ± 0.02%, ± 0.05%, ± 0.1% of full scale
  • 10 Units: Pa, kPa, MPa, PSI, Kg / cm², Bar, mBar, cmH20, mmH20, mmHg
  • Pressures: Relative, differential, Absolute
  • Display: Large LCD screen 6 Digits double display & bargraph
  • Connection: 1/4 ’’ NPT, 1/4 ’’ BSP, 1/4 ’’ G (or customizable)
  • Measurement & simulation of electrical signals
  • 10 function keys
  • Temperature compensation from 0 to 50 ° C
  • 60 hour rechargeable lithium battery
  • HART function
  • RS232 interface
  • Integrated data logger
  • Clean design & high performance
  • CE & Exic II BT6Gc approved
  • Calibration certificate with factory traceability
  • ISO17025 certificate optional
  • Non-contact level measurement of liquids
  • Applicable for continuous level measurement of liquids
    with slightly aggressiveness in storage containers, reactors or process vessels.
  • Measuring ranges : 0 ~ 30m
  • Accuracy : ± 2mm
  • Process pressure : -1 bar ~ 2 bar
  • Process temperature : -40℃ ~ +200℃
  • Media-conracting materials :
    Process fittings: 316L
    Antenna: PEEK PTFE
    Seal: FKM, EPDM, KALREZ
  • Display and Adjustment LCD display, tank side display and tank side hub
  • Communications : HART, RS485 Modbus, 4-20 mA...
  • Protect Level : IP67
  • Ex information : EX ia IIC T6 Ga Ex d ia [iaGa] IIC T6/T2 Gb
  • Different Models depending on the application
  • Non-contact level measurement of liquids
  • Continuous level measurement of aggressive liquids
    (storage containers, reactors or process vessels...)
  • Measuring ranges : 0 ~ 20m or 0 ~ 30m
  • Accuracy : ± 2mm
  • Process pressure : -1 bar ~ 2 bar
  • Process temperature : -40℃ ~ +200℃
  • Media-conracting materials :
    Process fittings: PP
    Antenna: PP
    Seal: FKM, EPDM, KALREZ
  • Display and Adjustment LCD display, tank side display and tank side hub
  • Communications : HART, RS485 Modbus, 4-20 mA...
  • Protect Level : IP67
  • Ex information : EX ia IIC T6 Ga Ex d ia [iaGa] IIC T6/T2 Gb
  • Different Models depending on the application
  • Pressure: Absolute
  • Details: 0.2% of full scale
  • 11 Units: Pa, kPa, MPa, PSI, Kg / cm², Bar, mmBar, cmH20 ...
  • Display: Large LCD screen 5 or 6 Digit & Bargraph in%
  • 7 function keys
  • Temperature compensation from 0 to 50 ° C
  • 60 hour rechargeable lithium battery
  • Integrated data logger
  • Clean design & high performance
  • CE & Exia II CT4Ga approved
  • Calibration certificate with factory traceability
  • Non-contact level measurement of liquids
  • Applicable for continuous level measurement of liquids aggressive liquids
    with lower demands on pressure and temperature ranges.
  • Measuring ranges : 0 ~ 30m
  • Accuracy : ± 2mm
  • Process pressure : -1 bar ~ 2 bar
  • Process temperature : -40℃ ~ +130℃
  • Media-conracting materials :
    Process fittings: PP
    Antenna: PP
    Seal: PP PTFE
  • Display and Adjustment LCD display, tank side display and tank side hub
  • Communications : HART, RS485 Modbus, 4-20 mA...
  • Protect Level : IP67
  • Ex information : EX ia IIC T6 Ga Ex d ia [iaGa] IIC T6/T2 Gb
  • Different Models depending on the application
  • Pressure: Absolute
  • Details: 0.1% of full scale
  • 11 Units: Pa, kPa, MPa, PSI, Kg / cm², Bar, mmBar, cmH20 ...
  • Display: Large LCD screen 5 or 6 Digit & Bargraph in%
  • 7 function keys
  • Temperature compensation from 0 to 50 ° C
  • 60 hour rechargeable lithium battery
  • Integrated data logger
  • Clean design & high performance
  • CE & Exia II CT4Ga approved
  • Calibration certificate with factory traceability
  • Non-contact level measurement of liquids
  • Applicable for continuous level measurement of liquids
    extremely aggressiveness in storage containers, reactors or process vessels.
  • Measuring ranges : 0 ~ 30m
  • Accuracy : ± 2mm
  • Process pressure : -1 bar ~ 16 bar
  • Process temperature : -40℃ ~ +200℃
  • Media-conracting materials :
    Process fittings: 316L
    Antenna: PTFE, PFA, PP
    Seal: FKM, EPDM, KALREZ
  • Display and Adjustment LCD display, tank side display and tank side hub
  • Communications : HART, RS485 Modbus, 4-20 mA...
  • Protect Level : IP67
  • Ex information : EX ia IIC T6 Ga Ex d ia [iaGa] IIC T6/T2 Gb Ex iaD tD A21 IP67T80ºC/T290ºC
  • Different Models depending on the application
  • Pressure: Differential
  • Details: 0.05% of full scale
  • 11 Units: Pa, kPa, MPa, PSI, Kg / cm², Bar, mmBar, cmH20 ...
  • Display: Large LCD screen 5 or 6 Digit & Bargraph in%
  • 7 function keys
  • Temperature compensation from 0 to 50 ° C
  • 60 hour rechargeable lithium battery
  • Integrated data logger
  • Clean design & high performance
  • CE & Exia II CT4Ga approved
  • Calibration certificate with factory traceability
  • Precision: ± 0.5%, or ± 0.25%, of full scale
  • Units: Bar MPa, PSI
  • Relative pressure: -1 bar up to 2000 bar
  • Differential pressure: 60 mbar up to 25 bar
  • Switch: relay signal adjustable over the whole scale
  • Display: Large red 4 DIGIT LED screen
  • Keys: On / Off, ZERO, UNIT, SET
  • Connection: 1/4 ’’ NPT, 1/4 ’’ BSP, 1/4 ’’ G (or customizable)
  • Dial size: 80 mm
  • All stainless steel fitting and housing
  • 220VAC or 24VDC power supply
  • CE & Ex ExibII BT4 certificate
  • Factory calibration certificate optional
  • ISO17025 calibration certificate optional
  • Measuring range: Liquid (0.25 ~ 4) m
  • Process connection: G1½A
  • PTFE 、 PU / PC
  • Process temperature: (-40 ~ 70) ° C
  • Process pressure: (-0.02 ~ 0.1) MPa
  • Output signal: (4 ~ 20) mA / HART
  • Power: dual-wire (DC24V) four-wire (DC24V / AC220V)
  • Measuring range: 200Pa-40MPa
  • Output signal: 4-20mA, 4 ~ 20mA / HART, client
  • Reference accuracy: ± 0.075% URL, optional ± 0.05% URL
  • Fluid temperature: -40-120
  • Measuring fluid: level, density and pressure of the liquid, gas or vapor
  • Protection class: IP67
  • Diaphragm material: SUS316L, Hastelloy C
  • Stability: ± 0.2% URL / 60 months
  • Process connection: M20 * 1.5 (M), 1 / 2-14NPT (F), 1 / 4-18NPT (F)
  • Approvals: ATEX, IECEx, NEPSI, RoHS, CE