Showing 13-24 of 46 item(s)
Active filters
  • Categories: Pressure
  • Categories: Temperature
  • Weight: 0kg - 0.5kg
  • Input: RTD
  • Type:pt100
  • Accuracy:0.2K or 0.1% of spanPerformance characteristics
  • Response time: 1s
  • Reference condition : Calibration temperature:+23°C(73.4K)±5K
  • Long term stability:≤0.05%year
  • Switch on delay:≤5s
  • Influence of ambient: Negligible
  • Load influence: Negligible
  • Power supply influence:Negligible
  • Resolution:1μA·Storage temperature
  • Ambient temperature limits:40 to +85 °C (-40 to 185 °F)
  • Storage temperature: -40 to +100 °C (-40 to 212 °F)
  • Condensation: Allowable
  • Degree of protection:IP00/IP66 installed
  • Shock and vibration resistance:4g/2 to150 Hz as per IEC 60 068-26
  • Electromagnetic compatibility (EMC) : Interference immunity and interference emission 
  • GB/T17626.2-1998), compliance with IEC 61000-4-3:1995

  • Output: 4 to 20mA
  • Supply voltage:  7.5 to 45VDC
  • Input:  RTD, TC, Ohm, mV
  • Cold junction:  Internal
  • Influence of ambient:  Negligible
  • Load influence: Negligible
  • Power supply influence:  Negligible
  • Resolution:  0.3uA
  • Installation:  sensor head Form B
  • Operation:  PC-programmable

* Output:  4 to 20mA

* Supply voltage:  7.5 to 45VDC

* Input:  RTD, TC, Ohm, mV

* Cold junction:  Internal

* Galvanic isolation: 2KVAC(In/Out)

* Influence of ambient:  Negligible

* Load influence:  Negligible

* Power supply influence:  Negligible

* Resolution:  0.3uA

* Installation:  sensor head Form B

* Operation:  PC-programmable

* Weight:  approx. 35g

* Dimensions:  44mm×24mm(Φ×H)

*Output: 4 to 20mA

*Supply voltage: 7.5 to 45VDC

*Input: RTD, TC, Ohm, mV

*Accuracy(Pt100): <0.2K or 0.08%

*Cold junction: Internal

*Galvanic isolation: 2 KVAC(In/Out)

*Influence of ambient: Negligible

*Load influence: Negligible

*Power supply influence: Negligible

*Resolution: 0.3uA

*Operation: HART-protocol

*Installation: sensor head Form B

*Dimensions: 44mm×24mm(Φ×H)

*Weight: approx. 35g

  • * Galvanic isolation
  • * No external power supply for configuration
  • * Write or read the configuration off-line by just connecting a PC
  • * Fault signal on sensor break or short circuit
  • * 2 wire technology, 4 to 20mA analogue output
  • * High accuracy in total ambient temperature range
  • * Customer specific measurement range setting or expanded SETUP

  • * Dimensions:   44mm×22.5mm(Φ×H)
  • * Output:   4 to 20mA
  • * Supply voltage:   11.5 to 35VDC (non-Ex-Area) 11.5 to 30VDC (Ex-Area)
  • * Input:   RTD, TC, Ohm, mV
  • * Operation:   HART-protocol
  • * Galvanic isolation(In/Out):  2KVAC
  • * Installation:  sensor head Form B
  • Precision: ± 0.5%, or ± 0.25%, of full scale
  • Units: Bar MPa, PSI
  • Relative pressure: -1 bar up to 2000 bar
  • Differential pressure: 60 mbar up to 25 bar
  • Switch: relay signal adjustable over the whole scale
  • Display: Large red 4 DIGIT LED screen
  • Keys: On / Off, ZERO, UNIT, SET
  • Connection: 1/4 ’’ NPT, 1/4 ’’ BSP, 1/4 ’’ G (or customizable)
  • Dial size: 80 mm
  • All stainless steel fitting and housing
  • 220VAC or 24VDC power supply
  • CE & Ex ExibII BT4 certificate
  • Factory calibration certificate optional
  • ISO17025 calibration certificate optional
  • Measuring range: 200Pa-40MPa
  • Output signal: 4-20mA, 4 ~ 20mA / HART, client
  • Reference accuracy: ± 0.075% URL, optional ± 0.05% URL
  • Fluid temperature: -40-120
  • Measuring fluid: level, density and pressure of the liquid, gas or vapor
  • Protection class: IP67
  • Diaphragm material: SUS316L, Hastelloy C
  • Stability: ± 0.2% URL / 60 months
  • Process connection: M20 * 1.5 (M), 1 / 2-14NPT (F), 1 / 4-18NPT (F)
  • Approvals: ATEX, IECEx, NEPSI, RoHS, CE
  • Measuring range: 10kPa-1MPa
  • Output signal: 4-20mA, 4-20mA + HART ...
  • Accuracy: ± 0.1% URL, ± 0.075% URL
  • Substrate temperature: -40-120 ° C
  • Measurement: pressure, level, differential pressure, density, flow
  • Protection class: IP67
  • Diaphragm material: SUS316L, Hastelloy C ...
  • Stability: ± 0.2% of URL / 5 years
  • Process connection: DN50 PN10, DN80 PN10, DN100 PN10
  • Certificates: CE, EX- test certificate
  • Measuring range: 4kPa-1MPa
  • Output signal: 4-20mA, 4-20mA + HART ...
  • Accuracy: ± 0.2% URL, ± 0.5% URL
  • Substrate temperature: -40 to 120 ° C
  • Measurement: pressure, level, differential pressure, density, flow
  • Protection class: IP67
  • Diaphragm material: SUS316L, Hastelloy C
  • Stability: ± 0.2% of URL / 5 years
  • Process connection: DN50 PN10, DN80 PN10, DN100 PN10, Tri-Clamp 1-1 / 2 ", Tri-Clamp 2"
  • Approvals: CE certificate, EX-proof
  • Measuring range: 200Pa-10MPa
  • Output signal: 4-20mA, 4 ~ 20mA / HART, client
  • Reference accuracy: ± 0.075% URL, optional ± 0.05% URL
  • Operating temperature: -40-85, LCD display: -40-120 ℃
  • Fluid temperature: -40-120
  • Measuring fluid: level, density and pressure of the liquid, gas or vapor
  • Protection class: IP67
  • Diaphragm material: SUS316L, Hastelloy C
  • Stability: ± 0.2% URL / 60 months
  • Process connection: M20 * 1.5 (M), 1 / 2-14NPT (F), 1 / 4-18NPT (F)
  • Approvals: ATEX, IECEx, NEPSI, RoHS, CE