- Output: 4 to 20mA
- Supply voltage: 7.5 to 45VDC
- Input: RTD, TC, Ohm, mV
- Cold junction: Internal
- Influence of ambient: Negligible
- Load influence: Negligible
- Power supply influence: Negligible
- Resolution: 0.3uA
- Installation: sensor head Form B
- Operation: PC-programmable
* Output: 4 to 20mA * Supply voltage: 7.5 to 45VDC * Input: RTD, TC, Ohm, mV * Cold junction: Internal * Galvanic isolation: 2KVAC(In/Out) * Influence of ambient: Negligible * Load influence: Negligible * Power supply influence: Negligible * Resolution: 0.3uA * Installation: sensor head Form B * Operation: PC-programmable * Weight: approx. 35g * Dimensions: 44mm×24mm(Φ×H) |
- Dimensions: 44mm×22.5mm(Φ×H)
- Output: 4 to 20mA
- Supply voltage: 8 to 35VDC (non-Ex-Area)
- 8 to 30VDC (Ex-Area)
- Input: PT100
- Installation: sensor head Form B
- * Galvanic isolation
- * No external power supply for configuration
- * Write or read the configuration off-line by just connecting a PC
- * Fault signal on sensor break or short circuit
- * 2 wire technology, 4 to 20mA analogue output
- * High accuracy in total ambient temperature range
- * Customer specific measurement range setting or expanded SETUP
- 4 ~ 20mA 2 inputs (fully isolated) HART
- Power supply: 7-30Vdc
- IP67
- Transmitter material: PVDF
- Internal temperature compensation
- Beam angle: 7
- Unaffected by liquid temperature or viscosity
- Maximum measurement: 12m
- Measuring range: Liquid (0.25 ~ 4) m
- Process connection: G1½A
- PTFE 、 PU / PC
- Process temperature: (-40 ~ 70) ° C
- Process pressure: (-0.02 ~ 0.1) MPa
- Output signal: (4 ~ 20) mA / HART
- Power: dual-wire (DC24V) four-wire (DC24V / AC220V)
- Measuring range: Liquid (0.4 ~ 8) m
- Process connection: G2A
- PTFE 、 PU / PC
- Process temperature: (-40 ~ 70) ° C
- Process pressure: (-0.02 ~ 0.1) MPa
- Output signal: (4 ~ 20) mA / HART
- Power: dual-wire (DC24V) four-wire (DC24V / AC220V)
- Measuring range: Liquid (0.5 ~ 15) m
- Process connection: Flange or swivelling holder
- PTFE 、 PU / PC
- Process temperature: (-40 ~ 70) ° C
- Process pressure: (-0.02 ~ 0.1) MPa
- Output signal: (4 ~ 20) mA / HART
- Power: dual-wire (DC24V) four-wire (DC24V / AC220V)
- Type: Magnetic level gauge
- Indicator system: Two-color flapper made of PBS plastic, 4 mm long and 0.25 mm thick with
- aligned magnets
- Fleet: SS316, SS316L, SS304, SS304L, PTFE, PVDF, PP, TITANIUM
- IP65, IP66, IP67
- SPDT, 230 VAC, 5 A or 24VDC, 0.5 A
- 4-20 m A
- Type: Magnetic level gauge
- Indicator system: Two-color rotary flappers / Capsule shuttle
- Fleet: SS 304, SS 304L, SS 316, SS 316L, Monel, Titanium, Inconel 600, Hastelloy C, PP, PVDF, Others on request
- IP65, IP66, IP67
- SPDT, 230 VAC, 5 A or 24VDC, 0.5 A
- 4-20 m A
- Type: Tubular
- Ice tube: Thick wall borosilicate glass tube
- End blocks: CS, SS 304, SS 316, PP, Others on request
- Connection: Flange 15 to 50 mm / Screwed up to 25 mm
- Process connection: Flange / Screwed / Triclover
- Aluminum / Acrylic / SS in mm
- Max. Hydraulic test pressure: 10 kg / cm
- Center to center distance: 175mm to 3000mm
- Max temperature: 100 ° C