- Speed, level, flow and temperature
- New velocity filter for more accurate readings
- Integrated micro data logger
- SDI-12 communications
- LCD display option available
- Input: RTD
- Type:pt100
- Accuracy:0.2K or 0.1% of spanPerformance characteristics
- Response time: 1s
- Reference condition : Calibration temperature:+23°C(73.4K)±5K
- Long term stability:≤0.05%year
- Switch on delay:≤5s
- Influence of ambient: Negligible
- Load influence: Negligible
- Power supply influence:Negligible
- Resolution:1μA·Storage temperature
- Ambient temperature limits:40 to +85 °C (-40 to 185 °F)
- Storage temperature: -40 to +100 °C (-40 to 212 °F)
- Condensation: Allowable
- Degree of protection:IP00/IP66 installed
- Shock and vibration resistance:4g/2 to150 Hz as per IEC 60 068-26
- Electromagnetic compatibility (EMC) : Interference immunity and interference emission
- GB/T17626.2-1998), compliance with IEC 61000-4-3:1995
- Measuring speed: 0.1 to 25 m / s
- Connection distance: 0.3 to 30 meters
- Resolution: 0.1 mm / s
- Measuring precession: ≤2%
- Data update cycle: 1 second
- Outputs & communications: 4-20 Ma x2 wires or x4 wires RS232, RS485 Modbus
- Transmitting frequency: 24 GHz (K-band)
- Communication speed: 115200 (standard)
- Power supply: 12 ~ 24 VDC
- Operating temperature: -35 ~ 70 ° C
- Compact size: 118 x 118 x 60 mm
- Material: Metal composite material
- Protection: IP68
- Options & Possibilities :
- Battery or solar panel power
- Local and / or remote data display
- Data processing: Tables, Curves & Alarms in real time
- Output: 4 to 20mA
- Supply voltage: 7.5 to 45VDC
- Input: RTD, TC, Ohm, mV
- Cold junction: Internal
- Influence of ambient: Negligible
- Load influence: Negligible
- Power supply influence: Negligible
- Resolution: 0.3uA
- Installation: sensor head Form B
- Operation: PC-programmable
- High measurement accuracy: Accuracy: 0.5%
- Wide measuring range: DN15 to DN6000
- Energy meter: Measurement of thermal and cooling energy
- Wide temperature range: Fluid from -30 ° C to 160 ° C
- Multiple communication interface as standard:
- Outputs: RS-485 Modbus RTU ~ 1x 4-20 mA ~ 1x Pulse ~ 1x Relay
- Inputs: 3x 4-20mA (acquisition of temperature, pressure, level signals, etc.)
- Multiple materials and pressures available:
- Carbon steel, 304 stainless steel, 316 stainless steel, 1.0 Mpa, 1.6 Mpa, 2.5 Mpa
- IP68 protection - Fully waterproof: Does not fear splashing water or humid environments
- Waterproof keyboard: 4 keys - settings and multiple functions
* Output: 4 to 20mA * Supply voltage: 7.5 to 45VDC * Input: RTD, TC, Ohm, mV * Cold junction: Internal * Galvanic isolation: 2KVAC(In/Out) * Influence of ambient: Negligible * Load influence: Negligible * Power supply influence: Negligible * Resolution: 0.3uA * Installation: sensor head Form B * Operation: PC-programmable * Weight: approx. 35g * Dimensions: 44mm×24mm(Φ×H) |
*Output: 4 to 20mA
*Supply voltage: 7.5 to 45VDC
*Input: RTD, TC, Ohm, mV
*Accuracy(Pt100): <0.2K or 0.08%
*Cold junction: Internal
*Galvanic isolation: 2 KVAC(In/Out)
*Influence of ambient: Negligible
*Load influence: Negligible
*Power supply influence: Negligible
*Resolution: 0.3uA
*Operation: HART-protocol
*Installation: sensor head Form B
*Dimensions: 44mm×24mm(Φ×H)
*Weight: approx. 35g
- Dimensions: 44mm×22.5mm(Φ×H)
- Output: 4 to 20mA
- Supply voltage: 8 to 35VDC (non-Ex-Area)
- 8 to 30VDC (Ex-Area)
- Input: PT100
- Installation: sensor head Form B
- * Galvanic isolation
- * No external power supply for configuration
- * Write or read the configuration off-line by just connecting a PC
- * Fault signal on sensor break or short circuit
- * 2 wire technology, 4 to 20mA analogue output
- * High accuracy in total ambient temperature range
- * Customer specific measurement range setting or expanded SETUP