- Input: RTD
- Type:pt100
- Accuracy:0.2K or 0.1% of spanPerformance characteristics
- Response time: 1s
- Reference condition : Calibration temperature:+23°C(73.4K)±5K
- Long term stability:≤0.05%year
- Switch on delay:≤5s
- Influence of ambient: Negligible
- Load influence: Negligible
- Power supply influence:Negligible
- Resolution:1μA·Storage temperature
- Ambient temperature limits:40 to +85 °C (-40 to 185 °F)
- Storage temperature: -40 to +100 °C (-40 to 212 °F)
- Condensation: Allowable
- Degree of protection:IP00/IP66 installed
- Shock and vibration resistance:4g/2 to150 Hz as per IEC 60 068-26
- Electromagnetic compatibility (EMC) : Interference immunity and interference emission
- GB/T17626.2-1998), compliance with IEC 61000-4-3:1995
- Output: 4 to 20mA
- Supply voltage: 7.5 to 45VDC
- Input: RTD, TC, Ohm, mV
- Cold junction: Internal
- Influence of ambient: Negligible
- Load influence: Negligible
- Power supply influence: Negligible
- Resolution: 0.3uA
- Installation: sensor head Form B
- Operation: PC-programmable
* Output: 4 to 20mA * Supply voltage: 7.5 to 45VDC * Input: RTD, TC, Ohm, mV * Cold junction: Internal * Galvanic isolation: 2KVAC(In/Out) * Influence of ambient: Negligible * Load influence: Negligible * Power supply influence: Negligible * Resolution: 0.3uA * Installation: sensor head Form B * Operation: PC-programmable * Weight: approx. 35g * Dimensions: 44mm×24mm(Φ×H) |
*Output: 4 to 20mA
*Supply voltage: 7.5 to 45VDC
*Input: RTD, TC, Ohm, mV
*Accuracy(Pt100): <0.2K or 0.08%
*Cold junction: Internal
*Galvanic isolation: 2 KVAC(In/Out)
*Influence of ambient: Negligible
*Load influence: Negligible
*Power supply influence: Negligible
*Resolution: 0.3uA
*Operation: HART-protocol
*Installation: sensor head Form B
*Dimensions: 44mm×24mm(Φ×H)
*Weight: approx. 35g
- Dimensions: 44mm×22.5mm(Φ×H)
- Output: 4 to 20mA
- Supply voltage: 8 to 35VDC (non-Ex-Area)
- 8 to 30VDC (Ex-Area)
- Input: PT100
- Installation: sensor head Form B
- * Galvanic isolation
- * No external power supply for configuration
- * Write or read the configuration off-line by just connecting a PC
- * Fault signal on sensor break or short circuit
- * 2 wire technology, 4 to 20mA analogue output
- * High accuracy in total ambient temperature range
- * Customer specific measurement range setting or expanded SETUP
- * Dimensions: 44mm×22.5mm(Φ×H)
- * Output: 4 to 20mA
- * Supply voltage: 11.5 to 35VDC (non-Ex-Area) 11.5 to 30VDC (Ex-Area)
- * Input: RTD, TC, Ohm, mV
- * Operation: HART-protocol
- * Galvanic isolation(In/Out): 2KVAC
- * Installation: sensor head Form B
- Precision: ± 0.5%, or ± 0.25%, of full scale
- Units: Bar MPa, PSI
- Relative pressure: -1 bar up to 2000 bar
- Differential pressure: 60 mbar up to 25 bar
- Switch: relay signal adjustable over the whole scale
- Display: Large red 4 DIGIT LED screen
- Keys: On / Off, ZERO, UNIT, SET
- Connection: 1/4 ’’ NPT, 1/4 ’’ BSP, 1/4 ’’ G (or customizable)
- Dial size: 80 mm
- All stainless steel fitting and housing
- 220VAC or 24VDC power supply
- CE & Ex ExibII BT4 certificate
- Factory calibration certificate optional
- ISO17025 calibration certificate optional
- Measuring range: 200Pa-40MPa
- Output signal: 4-20mA, 4 ~ 20mA / HART, client
- Reference accuracy: ± 0.075% URL, optional ± 0.05% URL
- Fluid temperature: -40-120
- Measuring fluid: level, density and pressure of the liquid, gas or vapor
- Protection class: IP67
- Diaphragm material: SUS316L, Hastelloy C
- Stability: ± 0.2% URL / 60 months
- Process connection: M20 * 1.5 (M), 1 / 2-14NPT (F), 1 / 4-18NPT (F)
- Approvals: ATEX, IECEx, NEPSI, RoHS, CE
- Measuring range: 10kPa-1MPa
- Output signal: 4-20mA, 4-20mA + HART ...
- Accuracy: ± 0.1% URL, ± 0.075% URL
- Substrate temperature: -40-120 ° C
- Measurement: pressure, level, differential pressure, density, flow
- Protection class: IP67
- Diaphragm material: SUS316L, Hastelloy C ...
- Stability: ± 0.2% of URL / 5 years
- Process connection: DN50 PN10, DN80 PN10, DN100 PN10
- Certificates: CE, EX- test certificate
- Measuring range: 4kPa-1MPa
- Output signal: 4-20mA, 4-20mA + HART ...
- Accuracy: ± 0.2% URL, ± 0.5% URL
- Substrate temperature: -40 to 120 ° C
- Measurement: pressure, level, differential pressure, density, flow
- Protection class: IP67
- Diaphragm material: SUS316L, Hastelloy C
- Stability: ± 0.2% of URL / 5 years
- Process connection: DN50 PN10, DN80 PN10, DN100 PN10, Tri-Clamp 1-1 / 2 ", Tri-Clamp 2"
- Approvals: CE certificate, EX-proof
- Measuring range: 200Pa-10MPa
- Output signal: 4-20mA, 4 ~ 20mA / HART, client
- Reference accuracy: ± 0.075% URL, optional ± 0.05% URL
- Operating temperature: -40-85, LCD display: -40-120 ℃
- Fluid temperature: -40-120
- Measuring fluid: level, density and pressure of the liquid, gas or vapor
- Protection class: IP67
- Diaphragm material: SUS316L, Hastelloy C
- Stability: ± 0.2% URL / 60 months
- Process connection: M20 * 1.5 (M), 1 / 2-14NPT (F), 1 / 4-18NPT (F)
- Approvals: ATEX, IECEx, NEPSI, RoHS, CE