- High measurement accuracy: Accuracy: 0.5%
- Wide measuring range: DN15 to DN6000
- Energy meter: Measurement of thermal and cooling energy
- Wide temperature range: Fluid from -30 ° C to 160 ° C
- Multiple communication interface as standard:
- Outputs: RS-485 Modbus RTU ~ 1x 4-20 mA ~ 1x Pulse ~ 1x Relay
- Inputs: 3x 4-20mA (acquisition of temperature, pressure, level signals, etc.)
- Multiple materials and pressures available:
- Carbon steel, 304 stainless steel, 316 stainless steel, 1.0 Mpa, 1.6 Mpa, 2.5 Mpa
- IP68 protection - Fully waterproof: Does not fear splashing water or humid environments
- Waterproof keyboard: 4 keys - settings and multiple functions
* Output: 4 to 20mA * Supply voltage: 7.5 to 45VDC * Input: RTD, TC, Ohm, mV * Cold junction: Internal * Galvanic isolation: 2KVAC(In/Out) * Influence of ambient: Negligible * Load influence: Negligible * Power supply influence: Negligible * Resolution: 0.3uA * Installation: sensor head Form B * Operation: PC-programmable * Weight: approx. 35g * Dimensions: 44mm×24mm(Φ×H) |
- Dimensions: 44mm×22.5mm(Φ×H)
- Output: 4 to 20mA
- Supply voltage: 8 to 35VDC (non-Ex-Area)
- 8 to 30VDC (Ex-Area)
- Input: PT100
- Installation: sensor head Form B
- * Galvanic isolation
- * No external power supply for configuration
- * Write or read the configuration off-line by just connecting a PC
- * Fault signal on sensor break or short circuit
- * 2 wire technology, 4 to 20mA analogue output
- * High accuracy in total ambient temperature range
- * Customer specific measurement range setting or expanded SETUP
- Precision: ± 0.5%, or ± 0.25%, of full scale
- Units: Bar MPa, PSI
- Relative pressure: -1 bar up to 2000 bar
- Differential pressure: 60 mbar up to 25 bar
- Switch: relay signal adjustable over the whole scale
- Display: Large red 4 DIGIT LED screen
- Keys: On / Off, ZERO, UNIT, SET
- Connection: 1/4 ’’ NPT, 1/4 ’’ BSP, 1/4 ’’ G (or customizable)
- Dial size: 80 mm
- All stainless steel fitting and housing
- 220VAC or 24VDC power supply
- CE & Ex ExibII BT4 certificate
- Factory calibration certificate optional
- ISO17025 calibration certificate optional
- Measuring range: 10kPa-1MPa
- Output signal: 4-20mA, 4-20mA + HART ...
- Accuracy: ± 0.1% URL, ± 0.075% URL
- Substrate temperature: -40-120 ° C
- Measurement: pressure, level, differential pressure, density, flow
- Protection class: IP67
- Diaphragm material: SUS316L, Hastelloy C ...
- Stability: ± 0.2% of URL / 5 years
- Process connection: DN50 PN10, DN80 PN10, DN100 PN10
- Certificates: CE, EX- test certificate
- Measuring range: 4kPa-1MPa
- Output signal: 4-20mA, 4-20mA + HART ...
- Accuracy: ± 0.2% URL, ± 0.5% URL
- Substrate temperature: -40 to 120 ° C
- Measurement: pressure, level, differential pressure, density, flow
- Protection class: IP67
- Diaphragm material: SUS316L, Hastelloy C
- Stability: ± 0.2% of URL / 5 years
- Process connection: DN50 PN10, DN80 PN10, DN100 PN10, Tri-Clamp 1-1 / 2 ", Tri-Clamp 2"
- Approvals: CE certificate, EX-proof