- 4 ~ 20mA 2 inputs (fully isolated) HART
- Power supply: 7-30Vdc
- IP67
- Transmitter material: PVDF
- Internal temperature compensation
- Beam angle: 7
- Unaffected by liquid temperature or viscosity
- Maximum measurement: 12m
- Precision: ± 0.5%, or ± 0.25%, of full scale
- Units: Bar MPa, PSI
- Relative pressure: -1 bar up to 2000 bar
- Differential pressure: 60 mbar up to 25 bar
- Switch: relay signal adjustable over the whole scale
- Display: Large red 4 DIGIT LED screen
- Keys: On / Off, ZERO, UNIT, SET
- Connection: 1/4 ’’ NPT, 1/4 ’’ BSP, 1/4 ’’ G (or customizable)
- Dial size: 80 mm
- All stainless steel fitting and housing
- 220VAC or 24VDC power supply
- CE & Ex ExibII BT4 certificate
- Factory calibration certificate optional
- ISO17025 calibration certificate optional
- Measuring range: Liquid (0.25 ~ 4) m
- Process connection: G1½A
- PTFE 、 PU / PC
- Process temperature: (-40 ~ 70) ° C
- Process pressure: (-0.02 ~ 0.1) MPa
- Output signal: (4 ~ 20) mA / HART
- Power: dual-wire (DC24V) four-wire (DC24V / AC220V)
- Measuring range: 10kPa-1MPa
- Output signal: 4-20mA, 4-20mA + HART ...
- Accuracy: ± 0.1% URL, ± 0.075% URL
- Substrate temperature: -40-120 ° C
- Measurement: pressure, level, differential pressure, density, flow
- Protection class: IP67
- Diaphragm material: SUS316L, Hastelloy C ...
- Stability: ± 0.2% of URL / 5 years
- Process connection: DN50 PN10, DN80 PN10, DN100 PN10
- Certificates: CE, EX- test certificate
- Measuring range: Liquid (0.4 ~ 8) m
- Process connection: G2A
- PTFE 、 PU / PC
- Process temperature: (-40 ~ 70) ° C
- Process pressure: (-0.02 ~ 0.1) MPa
- Output signal: (4 ~ 20) mA / HART
- Power: dual-wire (DC24V) four-wire (DC24V / AC220V)
- Measuring range: 4kPa-1MPa
- Output signal: 4-20mA, 4-20mA + HART ...
- Accuracy: ± 0.2% URL, ± 0.5% URL
- Substrate temperature: -40 to 120 ° C
- Measurement: pressure, level, differential pressure, density, flow
- Protection class: IP67
- Diaphragm material: SUS316L, Hastelloy C
- Stability: ± 0.2% of URL / 5 years
- Process connection: DN50 PN10, DN80 PN10, DN100 PN10, Tri-Clamp 1-1 / 2 ", Tri-Clamp 2"
- Approvals: CE certificate, EX-proof
- Measuring range: Liquid (0.5 ~ 15) m
- Process connection: Flange or swivelling holder
- PTFE 、 PU / PC
- Process temperature: (-40 ~ 70) ° C
- Process pressure: (-0.02 ~ 0.1) MPa
- Output signal: (4 ~ 20) mA / HART
- Power: dual-wire (DC24V) four-wire (DC24V / AC220V)
- Type: Magnetic level gauge
- Indicator system: Two-color flapper made of PBS plastic, 4 mm long and 0.25 mm thick with
- aligned magnets
- Fleet: SS316, SS316L, SS304, SS304L, PTFE, PVDF, PP, TITANIUM
- IP65, IP66, IP67
- SPDT, 230 VAC, 5 A or 24VDC, 0.5 A
- 4-20 m A
- Measuring range: 200Pa-10MPa
- Output signal: 4-20mA, 4 ~ 20mA / HART, client
- Reference accuracy: ± 0.075% URL, optional ± 0.05% URL
- Operating temperature: -40-85, LCD display: -40-120 ℃
- Fluid temperature: -40-120
- Measuring fluid: level, density and pressure of the liquid, gas or vapor
- Protection class: IP67
- Diaphragm material: SUS316L, Hastelloy C
- Stability: ± 0.2% URL / 60 months
- Process connection: M20 * 1.5 (M), 1 / 2-14NPT (F), 1 / 4-18NPT (F)
- Approvals: ATEX, IECEx, NEPSI, RoHS, CE
- Type: Magnetic level gauge
- Indicator system: Two-color rotary flappers / Capsule shuttle
- Fleet: SS 304, SS 304L, SS 316, SS 316L, Monel, Titanium, Inconel 600, Hastelloy C, PP, PVDF, Others on request
- IP65, IP66, IP67
- SPDT, 230 VAC, 5 A or 24VDC, 0.5 A
- 4-20 m A
- Measuring range: 200Pa-10MPa
- Output signal: 4-20mA, 4 ~ 20mA / HART, client
- Reference accuracy: ± 0.075% URL, optional ± 0.05% URL
- Operating temperature: -40-85, LCD display: -40-120 ℃
- Fluid temperature: -40-120
- Measuring fluid: level, density and pressure of the liquid, gas or vapor
- Protection class: IP67
- Diaphragm material: SUS316L, Hastelloy C
- Stability: ± 0.2% URL / 60 months
- Process connection: M20 * 1.5 (M), 1 / 2-14NPT (F), 1 / 4-18NPT (F)
- Approvals: ATEX, MC, NEPSI, CE