- High measurement accuracy: Accuracy: 0.5%
- Wide measuring range: DN15 to DN6000
- Energy meter: Measurement of thermal and cooling energy
- Wide temperature range: Fluid from -30 ° C to 160 ° C
- Multiple communication interface as standard:
- Outputs: RS-485 Modbus RTU ~ 1x 4-20 mA ~ 1x Pulse ~ 1x Relay
- Inputs: 3x 4-20mA (acquisition of temperature, pressure, level signals, etc.)
- Multiple materials and pressures available:
- Carbon steel, 304 stainless steel, 316 stainless steel, 1.0 Mpa, 1.6 Mpa, 2.5 Mpa
- IP68 protection - Fully waterproof: Does not fear splashing water or humid environments
- Waterproof keyboard: 4 keys - settings and multiple functions
- Thermal & cooling energy Advanced technology & electronics
- Easy to install & use
- Accuracy, stability & longevity
- Communications & remote reading
- Compact & robust design
- Vertical or horizontal mounting
- Multifunctional display/ 8 digit LCD screen
- Long life battery or power supply
- Suitable for lower water quality
- Hose material: Metal/ Rigid plastic tube made of PCV, PP or PVDF
- Liquid type: Water/Other (fluids without solid particles or impurities)
- 0-75° (no surface freezing)
- Low speed cut-off value: 0.1m/s
- Display: 256*128, LCD
- Response time: 0.5-60s
- Accuracy: +/-2%, (+/-1% after calibration)
- Data storage period: 300ms
- Memory for data saving: EEPROM, data storage more than 10 years
- I/O power supply: M12 type aviation plug
- Output: 4-20mA
- Communication: Modbus RS485
- Option for output: OCT, alarm relay
- Power supply: 10-24VVDC
- Electrical power : <3W
- Ambient temperature : -10° to 60°C
- Cable length: 2m, PT100 sensor cable length is 9m
- Easy to read Color Graphical TFT LCD display
- Rechargeable lithium ion battery with enhanced power control for prolonged battery life
- Measure or Source: mA, mV and V readings
- 24 VDC Loop power Supply to power transmitters and loops
- 2W simulate and Read/ Power mode for in-situ Loop checking and calibration
- Step/ Ramp functions with Auto/ Man selection
- Universal Serial Bus (USB) communication port for charging, data retrieve and firmware upgrade
- Data Logging to measure long time drift
- Other Features: Max/Min/Average, filter settings, tare facility, adjustable backlight, alarm annunciation (on display and buzzer), automatic Display off.
- Easy to read Color Graphical TFT LCD display
- Rechargeable lithium ion battery with enhanced power control for prolonged battery life
- Measure or Source: mA, mV and V readings
- 24 VDC Loop power Supply to power transmitters and loops
- 2W simulate and Read/ Power mode for in-situ Loop checking and calibration
- Step/ Ramp functions with Auto/ Man selection
- Universal Serial Bus (USB) communication port for charging, data retrieve and firmware upgrade
- Data Logging to measure long time drift
- Other Features: Max/Min/Average, filter settings, tare facility, adjustable backlight, alarm annunciation (on display and buzzer), automatic Display off.
- Direct Temperature output 12 Switched Steps
- < 0.3 °C Accuracy
- Quick Check Switch BOX
- Allows 2, 3 or 4 wire connections
- Compact Size
- Compact, handheld, User friendly menu
- Easy to read Color Graphical TFT LCD display
- Rechargeable lithium Ion battery with enhanced power control for prolonged battery life
- Measure: mA/ V/ mV/ mA (24V)/ Switch-test / RTD/ TC/ Frequency/ Pulse
- Source: mA/ V/ mV/ mA(2W)/ Resistance/ RTD/ TC/ Frequency/ Pulse
- 24 VDC Loop power Supply to power transmitters and loops
- Step/Ramp functions with Auto/Man selection
- Universal Serial Bus (USB) communication port for charging, data retrieve and firmware upgrade
- Data Logging to measure long time drift
- Other Features: Max/Min/Average, filter settings, tare facility, adjustable backlight, alarm annunciation (on display and buzzer), glance screen mode
- Continuity Test
- Pulsed RTD transmitter compatible
- HART loop resistor
- Integrated pneumatic pressure pump up to 70 bar
- Pressure module: any scale from -0.95 to 70 bar
- Accuracy: 0.01 % of full scale
- Temperature compensation up to 50 °C
- High stability & accuracy
- Simulates & measures electrical signals
- 4.3 " TFT colour touch screen
- 8 hours battery life
- USB PC interface & Calibration software
- ISO17025 traceable calibration certificate
Temperature range: (-)10°C ~120°CAccuracy: ± 0.3 °C
Stability: ± 0.02 °C
Resolution: 0.01 °C
Stabilization time: 7 minutes
Temperature unit: °C or °F selectable
Well diameter: 30 mm
Immersion length: 150 mm
Heating time: 10 minutes (Amb. to 120 °C)
Cooling time: 15 minutes (Amb. to (-) 10 °C)
25 minutes (120 °C to (-) 10 °C)
Communication port: RS232 port
Calibration software: MET-CAL as standard
Switch test: Provided
Power supply / Consumption: 110V to 240V AC, 50 to 60 Hz, 150 W
Dimensions (W x D x H) / Weight: 160 x 365 x 450 mm / 9 kg
Type of case: Portable
Carrying case: Provided
ISO17025 calibration certificate: Provided
Stability: ± 0.02 °C
Resolution: 0.01 °C
Stabilization time: 7 minutes
Temperature unit: °C or °F selectable
Well diameter: 30 mm
Immersion length: 150 mm
Heating time: 10 minutes (Amb. to 120 °C)
Cooling time: 15 minutes (Amb. to (-) 10 °C)
25 minutes (120 °C to (-) 10 °C)
Communication port: RS232 port
Calibration software: MET-CAL as standard
Switch test: Provided
Power supply / Consumption: 110V to 240V AC, 50 to 60 Hz, 150 W
Dimensions (W x D x H) / Weight: 160 x 365 x 450 mm / 9 kg
Type of case: Portable
Carrying case: Provided
ISO17025 calibration certificate: Provided
Température range : 50 °C ~ 650 °C
Accuracy: ± 0.3 °C
Stability: ± 0.02 °C
Resolution: 0.01 °C
Stabilization time: 7 minutes
Temperature unit: °C or °F selectable
Well diameter: 30 mm
Immersion length: 150 mm
Heating time: 10 minutes (Amb. to 120 °C)
Cooling time: 15 minutes (Amb. to (-) 10 °C)
25 minutes (120 °C to (-) 10 °C)
Communication port: RS232 port
Calibration software: MET-CAL as standard
Switch test: Provided
Power supply / Consumption: 110V to 240V AC, 50 to 60 Hz, 150 W
Dimensions (W x D x H) / Weight: 160 x 365 x 450 mm / 9 kg
Type of case: Portable
Carrying case: Provided
ISO17025 calibration certificate: Provided
Température range: 50 °C ~ 650 °C 300 °C ~ 1200 °CAccuracy: ± 2 °CStability: ± 0.3 °CResolution: 0.1 °CStabilization time: 15 minutesTemperature unit: Selectable °C or °FWell diameter: 30 mmImmersion length: 105 mmHeating time: 30 minutes (100 °C to 800 °C)Cooling time: 120 minutes (800 °C to 200 °C)Communication port: Standard RS232 portCalibration software: Standard MET-CAL software includedSwitch test: ProvidedPower supply / Consumption: 230V AC, 50 Hz & 115V AC switchable, 60 HzDimensions (L x W x H) / Weight: 160 x 365 x 450 mm / 11 kgEnclosure type: PortableCarrying case: IncludedISO17025 calibration certificate: Included