Theme Features - you can manage from admin

Select Theme
Custome Color 1
Custome Color 2
Box-Layout
Background Pattern

Custome background also available in admin.

Background color
Wow Animation Enable
Slider 3D Animation Enable
Menu Sticky Enable
Bottom Option Enable
Accueil
Accueil
Grid
List

There are 16 products.

Grid
List
Showing 1-12 of 16 item(s)
Active filters
  • Categories: Metering
  • Categories: Calibration
  • Price: €0.00 - €1.00
  • High measurement accuracy: Accuracy: 0.5%
  • Wide measuring range: DN15 to DN6000
  • Energy meter: Measurement of thermal and cooling energy
  • Wide temperature range: Fluid from -30 ° C to 160 ° C
  • Multiple communication interface as standard:
  • Outputs: RS-485 Modbus RTU ~ 1x 4-20 mA ~ 1x Pulse ~ 1x Relay
  • Inputs: 3x 4-20mA (acquisition of temperature, pressure, level signals, etc.)
  • Multiple materials and pressures available:
  • Carbon steel, 304 stainless steel, 316 stainless steel, 1.0 Mpa, 1.6 Mpa, 2.5 Mpa
  • IP68 protection - Fully waterproof: Does not fear splashing water or humid environments
  • Waterproof keyboard: 4 keys - settings and multiple functions
  • Thermal & cooling energy Advanced technology & electronics
  • Easy to install & use
  • Accuracy, stability & longevity
  • Communications & remote reading
  • Compact & robust design
  • Vertical or horizontal mounting
  • Multifunctional display/ 8 digit LCD screen
  • Long life battery or power supply
  • Suitable for lower water quality

  • Hose material: Metal/ Rigid plastic tube made of PCV, PP or PVDF
  • Liquid type: Water/Other (fluids without solid particles or impurities)
  • 0-75° (no surface freezing)
  • Low speed cut-off value: 0.1m/s
  • Display: 256*128, LCD
  • Response time: 0.5-60s
  • Accuracy: +/-2%, (+/-1% after calibration)
  • Data storage period: 300ms
  • Memory for data saving: EEPROM, data storage more than 10 years
  • I/O power supply: M12 type aviation plug
  • Output: 4-20mA
  • Communication: Modbus RS485
  • Option for output: OCT, alarm relay 
  • Power supply: 10-24VVDC
  • Electrical power : <3W
  • Ambient temperature : -10° to 60°C
  • Cable length: 2m, PT100 sensor cable length is 9m

  • Easy to read Color Graphical TFT LCD display
  • Rechargeable lithium ion battery with enhanced power control for prolonged battery life
  • Measure or Source: mA, mV and V readings
  • 24 VDC Loop power Supply to power transmitters and loops
  • 2W simulate and Read/ Power mode for in-situ Loop checking and calibration
  • Step/ Ramp functions with Auto/ Man selection
  • Universal Serial Bus (USB) communication port for charging, data retrieve and firmware upgrade
  • Data Logging to measure long time drift
  • Other Features: Max/Min/Average, filter settings, tare facility, adjustable backlight, alarm annunciation (on display and buzzer), automatic Display off.

  • Easy to read Color Graphical TFT LCD display
  • Rechargeable lithium ion battery with enhanced power control for prolonged battery life
  • Measure or Source: mA, mV and V readings
  • 24 VDC Loop power Supply to power transmitters and loops
  • 2W simulate and Read/ Power mode for in-situ Loop checking and calibration
  • Step/ Ramp functions with Auto/ Man selection
  • Universal Serial Bus (USB) communication port for charging, data retrieve and firmware upgrade
  • Data Logging to measure long time drift
  • Other Features: Max/Min/Average, filter settings, tare facility, adjustable backlight, alarm annunciation (on display and buzzer), automatic Display off.

  • Compact, handheld, User friendly menu
  • Easy to read Color Graphical TFT LCD display
  • Rechargeable lithium Ion battery with enhanced power control for prolonged battery life
  • Measure: mA/ V/ mV/ mA (24V)/ Switch-test / RTD/ TC/ Frequency/ Pulse
  • Source: mA/ V/ mV/ mA(2W)/ Resistance/ RTD/ TC/ Frequency/ Pulse
  • 24 VDC Loop power Supply to power transmitters and loops
  • Step/Ramp functions with Auto/Man selection
  • Universal Serial Bus (USB) communication port for charging, data retrieve and firmware upgrade
  • Data Logging to measure long time drift
  • Other Features: Max/Min/Average, filter settings, tare facility, adjustable backlight, alarm annunciation (on display and buzzer), glance screen mode
  • Continuity Test
  • Pulsed RTD transmitter compatible
  • HART loop resistor
  • Integrated pneumatic pressure pump up to 70 bar
  • Pressure module: any scale from -0.95 to 70 bar
  • Accuracy: 0.01 % of full scale
  • Temperature compensation up to 50 °C 
  • High stability & accuracy 
  • Simulates & measures electrical signals
  • 4.3 " TFT colour touch screen
  • 8 hours battery life
  • USB PC interface & Calibration software 
  • ISO17025 traceable calibration certificate

Temperature range: (-)10°C ~120°C
Accuracy: ± 0.3 °C
Stability: ± 0.02 °C
Resolution: 0.01 °C
Stabilization time: 7 minutes
Temperature unit: °C or °F selectable
Well diameter: 30 mm
Immersion length: 150 mm
Heating time: 10 minutes (Amb. to 120 °C)
Cooling time: 15 minutes (Amb. to (-) 10 °C)
                    25 minutes (120 °C to (-) 10 °C)
Communication port: RS232 port
Calibration software: MET-CAL as standard
Switch test: Provided
Power supply / Consumption: 110V to 240V AC, 50 to 60 Hz, 150 W
Dimensions (W x D x H) / Weight: 160 x 365 x 450 mm / 9 kg
Type of case: Portable
Carrying case: Provided
ISO17025 calibration certificate: Provided

Température range : 50 °C ~ 650 °C
Accuracy: ± 0.3 °C
Stability: ± 0.02 °C
Resolution: 0.01 °C
Stabilization time: 7 minutes
Temperature unit: °C or °F selectable
Well diameter: 30 mm
Immersion length: 150 mm
Heating time: 10 minutes (Amb. to 120 °C)
Cooling time: 15 minutes (Amb. to (-) 10 °C)
                    25 minutes (120 °C to (-) 10 °C)
Communication port: RS232 port
Calibration software: MET-CAL as standard
Switch test: Provided
Power supply / Consumption: 110V to 240V AC, 50 to 60 Hz, 150 W
Dimensions (W x D x H) / Weight: 160 x 365 x 450 mm / 9 kg
Type of case: Portable
Carrying case: Provided
ISO17025 calibration certificate: Provided

Température range: 50 °C ~ 650 °C 300 °C ~ 1200 °C
Accuracy: ± 2 °C
Stability: ± 0.3 °C
Resolution: 0.1 °C
Stabilization time: 15 minutes
Temperature unit: Selectable °C or °F
Well diameter: 30 mm
Immersion length: 105 mm
Heating time: 30 minutes (100 °C to 800 °C)
Cooling time: 120 minutes (800 °C to 200 °C)
Communication port: Standard RS232 port
Calibration software: Standard MET-CAL software included
Switch test: Provided
Power supply / Consumption: 230V AC, 50 Hz & 115V AC switchable, 60 Hz
Dimensions (L x W x H) / Weight: 160 x 365 x 450 mm / 11 kg
Enclosure type: Portable
Carrying case: Included
ISO17025 calibration certificate: Included