Active filters
-
Categories:
Flow
-
Categories:
Temperature
Temperature and humidity transmitter HT7S
- Rugged weather proof enclosure with Exproof enclosure as an option
- Available in Wall and Duct mounting versions.
- Three variants.
- Measuring Range: 0-100% RH in models, suitable formmany applications
- Class-A RTD Pt 100 sensor used for temperature measurement
- Linearised analog 4-20mA signal output (2wire loop powered)
- Replaceable humidity sensor assembly
- Capacitance based sensing.
- High Accuracy
- Excellent long-term stability
TT7S10-D and TT7S10-XP loop powered temperature transmitters
- Universal input (RTD, Thermocouple, Ohm, mV)
- Available in below options :
TT7S10-D: Din Rail mount with 3″, 4 digit LED display
TT7S10-XP: Wall or 2″ Pipe mount Ex-proof Transmitter with touch sense keys
- 0.56″, 4 digit LED display in Single Compartment
- 0.39″, 4 digit LED display in Dual Compartment
- 1.5 KV RMS Isolation between Input & Output Linearized Output
- Highly Accurate
- Fully Programmable for Input type & Range
- Digital Filter
- Easy configuration using keys and display
- Windows mTRAN software for Configuration, Calibration & Monitoring
- Reverse Loop polarity protection
- Direct / Reverse output
- Sensor break detection
Temperature Transmitter TT7S
- Universal input (RTD, thermocouple, Ohm, mV)
- 1.5 KV RMS Isolation between Input & Output
- Linearized Output
- Highly Accurate
- Fully Programmable for Input type & Range
- Fast Response time: <500 ms
- Digital Filter
- Windows mTRAN software for Configuration, Calibration & Monitoring
- Reverse polarity protection
- Direct/Reverse output
- Sensor break detection
- Loop/Aux Powered models
DUS-D-F Doppler ultrasonic flowmeter wall mount
- For wastewater and two-phase liquids (emulsion)
- Non-intrusive transducers from DN40 to DN4000
- Suitable for all types of pipes (uni-material)
- Transducers -35 ~ 85 ° C
- 10 m of cables
- Excellent measurement capacity for low flow rates (from 0.05m / s)
- Easy installation & configuration
- Outputs: 4-20mA as standard
- Accuracy: 0.5% to 2.0%
- Power supply: 100-240VAC or 10 - 28 VDC
PITMT130 - Temperature Transmitter
- Communication : e-HART
- Output : 4 to 20mA
- Supply voltage : 7.5 to 45VDC
- Input : RTC, TC, Ohm, mV
- Cold junction : Internal
- Accuracy (Pt100) : <0,2K or 0,08%
- Influence of ambient : Negligible
- Load influence : Negligible
- Power supply influence : Negligible
- Resolution : 0.3uA
- Installation : DIN Rail
DUS-D-V Portable Doppler Ultrasonic Flow Meter
- For wastewater and two-phase liquids (emulsion)
- Non-intrusive transducers from DN40 to DN4000
- Suitable for all types of pipes (uni-material)
- Transducers -35 ~ 85 ° C
- 5 m cables
- Excellent measurement capacity for low flow rates (from 0.05m / s)
- Easy installation & configuration
- Outputs: 4-20mA as standard
- Accuracy: 0.5% to 2.0%
- Battery: Autonomy 40 h
PITMT131 - Temperature Transmitter
- Communication : e-HART
- Output : 4 to 20mA
- Supply voltage : 7.5 to 45VDC
- Input : RTC, TC, Ohm, mV
- Cold junction : Internal
- Accuracy (Pt100) : <0,2K or 0,08%
- Influence of ambient : Negligible
- Load influence : Negligible
- Power supply influence : Negligible
- Resolution : 0.3uA
- Galvanic isolation (In/Out) : 2KVAC
- Installation : DIN Rail
PITMT132 - Temperature Transmitter
- Communication : e-HART
- Output : 4 to 20mA
- Supply voltage : 7.5 to 45VDC
- Input : RTC, TC, Ohm, mV
- Cold junction : Internal
- Accuracy (Pt100) : <0,2K or 0,08%
- Influence of ambient : Negligible
- Load influence : Negligible
- Power supply influence : Negligible
- Resolution : 0.3uA
- Galvanic isolation (In/Out) : 2KVAC
- Installation : DIN Rail
DUS-TT-FC Non-intrusive ultrasonic flowmeter wall mount
- Accuracy: 1%
- Non-intrusive transducers
- DN15 to DN6000 ~ depending on type of transducers
- Energy meter option: thermal and cooling energy
- Communication: RS-485 Modbus RTU
- Outputs: 1x 4-20mA ~ 1x 4-20mA ~ 1x Pulse ~ 1x Relay
- Inputs: 3 x 4-20mA
- Integrated data logger: SD card slot
- IP67 flowmeter ~ IP68 transducers
- Compact & Robust
- Dimensions: 13 cm × 15 cm × 8 cm ~ Weight: 1 kg
- 2x High temperature non-intrusive transducers -30 ° C to 160 ° C
- FREE mounting rail with transducers
PITMT272 - Smart Temperature Transmitter HART
- Universal settings with HART-protocol for various input signals
- 2 wire technology, 4 to 20mA analogue output
- High accuracy in total ambient temperature range
- Galvanic isolation
- An internal temperature sensor of active temperature compensation
- Wide voltage supply range
- Customer specific measurement range settings
- Simple and user friendly software
- Multiparametric backlight rotatable LCD display
PITMT199 - Temperature Field Transmitter HART
- Universally progammable with HART-protocol for various input signals
- Two-wire technology, analogue output 4 to 20mA
- Highly accurate in entire operating temperature range
- Wide voltage supply range
- Customer specific measurement range settings
- Simple and user friendly software
- Multiparametric backlight rotatable LCD display
DUS-TT-V portable ultrasonic flow meter battery 50 hours
- Accuracy: 1%
- Non-intrusive transducers
- DN20 to DN6000 ~ depending on type of transducers
- Rechargeable battery, Autonomy 50 hours
- Data logger
- Communication: RS-485 Modbus RTU
- Output: 4-20mA
- IP67 flowmeter ~ IP68 transducers
- Compact & Robust
- Dimensions: 270 × 215 × 175 mm ~ Weight: 3 kg
- 2x Non-intrusive transducers -35 ° C to 85 ° C
- Other output (optional): Pulse, Relay
- Energy meter option
PIMST10RL - Heat Temperature Transmitter
- Input: RTD
- Type:pt100
- Accuracy:0.2K or 0.1% of spanPerformance characteristics
- Response time: 1s
- Reference condition : Calibration temperature:+23°C(73.4K)±5K
- Long term stability:≤0.05%year
- Switch on delay:≤5s
- Influence of ambient: Negligible
- Load influence: Negligible
- Power supply influence:Negligible
- Resolution:1μA·Storage temperature
- Ambient temperature limits:40 to +85 °C (-40 to 185 °F)
- Storage temperature: -40 to +100 °C (-40 to 212 °F)
- Condensation: Allowable
- Degree of protection:IP00/IP66 installed
- Shock and vibration resistance:4g/2 to150 Hz as per IEC 60 068-26
- Electromagnetic compatibility (EMC) : Interference immunity and interference emission
- GB/T17626.2-1998), compliance with IEC 61000-4-3:1995
DCO-7526 Open channel Doppler flow meter
- Speed, level, flow and temperature
- New velocity filter for more accurate readings
- Integrated micro data logger
- SDI-12 communications
- LCD display option available
PITMT190B - Heat Temperature Transmitter
- Output: 4 to 20mA
- Supply voltage: 7.5 to 45VDC
- Input: RTD, TC, Ohm, mV
- Cold junction: Internal
- Influence of ambient: Negligible
- Load influence: Negligible
- Power supply influence: Negligible
- Resolution: 0.3uA
- Installation: sensor head Form B
- Operation: PC-programmable