- 8 Current inputs
- Modbus RTU compatible
- Current: 0 - 20 mA
- Offset: 4 mA
- Insulation: 1500 Vrms
- Up to 128 modules on the RS485 network
- Indication LEDs
- Rai-din fixing
- Module configuration software
- User Manual
€324.00
Price
For all clear, non biphasic liquids and all types of pipes from DN20 to DN 1200 :
- Measurement accuracy 1% F.S
- Communications : 4~20 mA & RS485 Modbus
- Programmable data logger 16 GB SD card
- Battery 16 hours autonomy
- Non-invasive transducers Stainless steel IP68
- Mounting rails for optimal measurement
- Energy metering included
- 2x TT02 IP68 transducers
- -40 °C ~ 80 °C (130°C optional)
- Suitable for pipes DN 20 mm to DN 1200 mm
- Mounting rails with strip and clamps
- Standard cable length: 5 meters
- 2x non-intrusive PT100 IP68 temperature sensors
- Measurement of thermal & cooling energy
€3,000.00
Price
- 8 current differential inputs
- Modbus RTU compatible
- Current: 0 - 20 mA
- Offset: 4 mA
- Insulation: 1000 Vrms (350 V between channels)
- Up to 128 modules on the RS485 network
- Indication LEDs
- Rai-din fixing
- Module configuration software
- User Manual
€456.00
Price
- 8 voltage inputs
- Modbus RTU compatible
- Voltage: 0 - 10 Vdc & 0 - 5 Vdc
- Offset: 2 Vdc [0-10] & 1 Vdc [1-5]
- Insulation: 1500 Vrms
- Up to 128 modules on the RS485 network
- Indication LEDs
- Rai-din fixing
- Module configuration software
- User Manual
€324.00
Price
- Hose material: Metal/ Rigid plastic tube made of PCV, PP or PVDF
- Liquid type: Water/Other (fluids without solid particles or impurities)
- 0-75° (no surface freezing)
- Low speed cut-off value: 0.1m/s
- Display: 256*128, LCD
- Response time: 0.5-60s
- Accuracy: +/-2%, (+/-1% after calibration)
- Data storage period: 300ms
- Memory for data saving: EEPROM, data storage more than 10 years
- I/O power supply: M12 type aviation plug
- Output: 4-20mA
- Communication: Modbus RS485
- Option for output: OCT, alarm relay
- Power supply: 10-24VVDC
- Electrical power : <3W
- Ambient temperature : -10° to 60°C
- Cable length: 2m, PT100 sensor cable length is 9m
- 8 isolated voltage inputs
- Modbus RTU compatible
- Voltage: 0 - 10 Vdc & 0 - 5 Vdc
- Offset: 2 Vdc [0-10] & 1 Vdc [1-5]
- Insulation: 1500 Vrms (350 V between channels)
- Up to 128 modules on the RS485 network
- Indication LEDs
- Rai-din fixing
- Module configuration software
- User Manual
€456.00
Price
- Hose material: Metal/ rigid plastic tube made of PCV, PP or PVDF
- Liquid type: Water/Other (fluids without solid particles or impurities)
- 0-75° (no surface freezing)
- Low speed cut-off value: 0.1m/s
- Display: 256*128, LCD
- Response time: 0.5-60s
- Accuracy: +/-2%, (+/-1% after calibration)
- Data storage period: 300ms
- Memory for data saving: EEPROM, data storage more than 10 years
- I/O power supply: M12 type aviation plug
- Output: 4-20mA
- Communication: Modbus RS485
- Option for output: OCT, alarm relay
- Power supply: 10-24VVDC
- Electrical power : <3W
- Ambient temperature : -10° to 60°C
- Cable length: 2m, PT100 sensor cable length is 9m
- 8 current outputs
- Modbus RTU compatible
- Current: 0 - 20 mA
- Offset: 4 mA
- Insulation: 1500 Vrms
- Up to 128 modules on the RS485 network
- Indication LEDs
- Rai-din fixing
- Module configuration software
- User Manual
€348.00
Price
PN:16 bar R250 T50
Power supply: 3.6V lithium battery
Lifespan ≥ 10 years
Fluid: cold water & hot water
Fluid temperature: up to 50°C
Protection: IP68
Installation: Any angle
Communication: RS485 Modbus RTU
MID and ACS approved
€234.00
Price
- 8 voltage outputs
- Modbus RTU compatible
- Voltage: 0 - 10 Vdc
- Offset: 2 Vdc
- Insulation: 1500 Vrms
- Up to 128 modules on the RS485 network
- Indication LEDs
- Rai-din fixing
- Module configuration software
- User Manual
€348.00
Price
- 2 inputs & 1 analog output
- 4 digital inputs & 2 digital outputs
- 2 RTD inputs
- Modbus RTU compatible
- Up to 128 modules on the RS485 network
- Indication LEDs
- Rai-din fixing
- Module configuration software
- User Manual
€456.00
Price