- Input: RTD
- Type:pt100
- Accuracy:0.2K or 0.1% of spanPerformance characteristics
- Response time: 1s
- Reference condition : Calibration temperature:+23°C(73.4K)±5K
- Long term stability:≤0.05%year
- Switch on delay:≤5s
- Influence of ambient: Negligible
- Load influence: Negligible
- Power supply influence:Negligible
- Resolution:1μA·Storage temperature
- Ambient temperature limits:40 to +85 °C (-40 to 185 °F)
- Storage temperature: -40 to +100 °C (-40 to 212 °F)
- Condensation: Allowable
- Degree of protection:IP00/IP66 installed
- Shock and vibration resistance:4g/2 to150 Hz as per IEC 60 068-26
- Electromagnetic compatibility (EMC) : Interference immunity and interference emission
- GB/T17626.2-1998), compliance with IEC 61000-4-3:1995
- Output: 4 to 20mA
- Supply voltage: 7.5 to 45VDC
- Input: RTD, TC, Ohm, mV
- Cold junction: Internal
- Influence of ambient: Negligible
- Load influence: Negligible
- Power supply influence: Negligible
- Resolution: 0.3uA
- Installation: sensor head Form B
- Operation: PC-programmable
* Output: 4 to 20mA * Supply voltage: 7.5 to 45VDC * Input: RTD, TC, Ohm, mV * Cold junction: Internal * Galvanic isolation: 2KVAC(In/Out) * Influence of ambient: Negligible * Load influence: Negligible * Power supply influence: Negligible * Resolution: 0.3uA * Installation: sensor head Form B * Operation: PC-programmable * Weight: approx. 35g * Dimensions: 44mm×24mm(Φ×H) |
*Output: 4 to 20mA
*Supply voltage: 7.5 to 45VDC
*Input: RTD, TC, Ohm, mV
*Accuracy(Pt100): <0.2K or 0.08%
*Cold junction: Internal
*Galvanic isolation: 2 KVAC(In/Out)
*Influence of ambient: Negligible
*Load influence: Negligible
*Power supply influence: Negligible
*Resolution: 0.3uA
*Operation: HART-protocol
*Installation: sensor head Form B
*Dimensions: 44mm×24mm(Φ×H)
*Weight: approx. 35g
- Dimensions: 44mm×22.5mm(Φ×H)
- Output: 4 to 20mA
- Supply voltage: 8 to 35VDC (non-Ex-Area)
- 8 to 30VDC (Ex-Area)
- Input: PT100
- Installation: sensor head Form B
- * Galvanic isolation
- * No external power supply for configuration
- * Write or read the configuration off-line by just connecting a PC
- * Fault signal on sensor break or short circuit
- * 2 wire technology, 4 to 20mA analogue output
- * High accuracy in total ambient temperature range
- * Customer specific measurement range setting or expanded SETUP
- High measurement accuracy: Accuracy: 0.5%
- Wide measuring range: DN15 to DN6000
- Energy meter: Measurement of thermal and cooling energy
- Wide temperature range: Fluid from -30 ° C to 160 ° C
- Multiple communication interface as standard:
- Outputs: RS-485 Modbus RTU ~ 1x 4-20 mA ~ 1x Pulse ~ 1x Relay
- Inputs: 3x 4-20mA (acquisition of temperature, pressure, level signals, etc.)
- Multiple materials and pressures available:
- Carbon steel, 304 stainless steel, 316 stainless steel, 1.0 Mpa, 1.6 Mpa, 2.5 Mpa
- IP68 protection - Fully waterproof: Does not fear splashing water or humid environments
- Waterproof keyboard: 4 keys - settings and multiple functions
- * Dimensions: 44mm×22.5mm(Φ×H)
- * Output: 4 to 20mA
- * Supply voltage: 11.5 to 35VDC (non-Ex-Area) 11.5 to 30VDC (Ex-Area)
- * Input: RTD, TC, Ohm, mV
- * Operation: HART-protocol
- * Galvanic isolation(In/Out): 2KVAC
- * Installation: sensor head Form B
- Thermal & cooling energy Advanced technology & electronics
- Easy to install & use
- Accuracy, stability & longevity
- Communications & remote reading
- Compact & robust design
- Vertical or horizontal mounting
- Multifunctional display/ 8 digit LCD screen
- Long life battery or power supply
- Suitable for lower water quality
- 4 ~ 20mA 2 inputs (fully isolated) HART
- Power supply: 7-30Vdc
- IP67
- Transmitter material: PVDF
- Internal temperature compensation
- Beam angle: 7
- Unaffected by liquid temperature or viscosity
- Maximum measurement: 12m
- Measuring range: Liquid (0.25 ~ 4) m
- Process connection: G1½A
- PTFE 、 PU / PC
- Process temperature: (-40 ~ 70) ° C
- Process pressure: (-0.02 ~ 0.1) MPa
- Output signal: (4 ~ 20) mA / HART
- Power: dual-wire (DC24V) four-wire (DC24V / AC220V)
For all clear, non biphasic liquids and all types of pipes from DN20 to DN 1200 :
- Measurement accuracy 1% F.S
- Communications : 4~20 mA & RS485 Modbus
- Programmable data logger 16 GB SD card
- Battery 16 hours autonomy
- Non-invasive transducers Stainless steel IP68
- Mounting rails for optimal measurement
- Energy metering included
- 2x TT02 IP68 transducers
- -40 °C ~ 80 °C (130°C optional)
- Suitable for pipes DN 20 mm to DN 1200 mm
- Mounting rails with strip and clamps
- Standard cable length: 5 meters
- 2x non-intrusive PT100 IP68 temperature sensors
- Measurement of thermal & cooling energy