- Input: RTD
- Type:pt100
- Accuracy:0.2K or 0.1% of spanPerformance characteristics
- Response time: 1s
- Reference condition : Calibration temperature:+23°C(73.4K)±5K
- Long term stability:≤0.05%year
- Switch on delay:≤5s
- Influence of ambient: Negligible
- Load influence: Negligible
- Power supply influence:Negligible
- Resolution:1μA·Storage temperature
- Ambient temperature limits:40 to +85 °C (-40 to 185 °F)
- Storage temperature: -40 to +100 °C (-40 to 212 °F)
- Condensation: Allowable
- Degree of protection:IP00/IP66 installed
- Shock and vibration resistance:4g/2 to150 Hz as per IEC 60 068-26
- Electromagnetic compatibility (EMC) : Interference immunity and interference emission
- GB/T17626.2-1998), compliance with IEC 61000-4-3:1995
- Output: 4 to 20mA
- Supply voltage: 7.5 to 45VDC
- Input: RTD, TC, Ohm, mV
- Cold junction: Internal
- Influence of ambient: Negligible
- Load influence: Negligible
- Power supply influence: Negligible
- Resolution: 0.3uA
- Installation: sensor head Form B
- Operation: PC-programmable
* Output: 4 to 20mA * Supply voltage: 7.5 to 45VDC * Input: RTD, TC, Ohm, mV * Cold junction: Internal * Galvanic isolation: 2KVAC(In/Out) * Influence of ambient: Negligible * Load influence: Negligible * Power supply influence: Negligible * Resolution: 0.3uA * Installation: sensor head Form B * Operation: PC-programmable * Weight: approx. 35g * Dimensions: 44mm×24mm(Φ×H) |
*Output: 4 to 20mA
*Supply voltage: 7.5 to 45VDC
*Input: RTD, TC, Ohm, mV
*Accuracy(Pt100): <0.2K or 0.08%
*Cold junction: Internal
*Galvanic isolation: 2 KVAC(In/Out)
*Influence of ambient: Negligible
*Load influence: Negligible
*Power supply influence: Negligible
*Resolution: 0.3uA
*Operation: HART-protocol
*Installation: sensor head Form B
*Dimensions: 44mm×24mm(Φ×H)
*Weight: approx. 35g
- Dimensions: 44mm×22.5mm(Φ×H)
- Output: 4 to 20mA
- Supply voltage: 8 to 35VDC (non-Ex-Area)
- 8 to 30VDC (Ex-Area)
- Input: PT100
- Installation: sensor head Form B
- * Galvanic isolation
- * No external power supply for configuration
- * Write or read the configuration off-line by just connecting a PC
- * Fault signal on sensor break or short circuit
- * 2 wire technology, 4 to 20mA analogue output
- * High accuracy in total ambient temperature range
- * Customer specific measurement range setting or expanded SETUP
- * Dimensions: 44mm×22.5mm(Φ×H)
- * Output: 4 to 20mA
- * Supply voltage: 11.5 to 35VDC (non-Ex-Area) 11.5 to 30VDC (Ex-Area)
- * Input: RTD, TC, Ohm, mV
- * Operation: HART-protocol
- * Galvanic isolation(In/Out): 2KVAC
- * Installation: sensor head Form B
- 4 ~ 20mA 2 inputs (fully isolated) HART
- Power supply: 7-30Vdc
- IP67
- Transmitter material: PVDF
- Internal temperature compensation
- Beam angle: 7
- Unaffected by liquid temperature or viscosity
- Maximum measurement: 12m
- Measuring range: Liquid (0.25 ~ 4) m
- Process connection: G1½A
- PTFE 、 PU / PC
- Process temperature: (-40 ~ 70) ° C
- Process pressure: (-0.02 ~ 0.1) MPa
- Output signal: (4 ~ 20) mA / HART
- Power: dual-wire (DC24V) four-wire (DC24V / AC220V)
- Measuring range: Liquid (0.4 ~ 8) m
- Process connection: G2A
- PTFE 、 PU / PC
- Process temperature: (-40 ~ 70) ° C
- Process pressure: (-0.02 ~ 0.1) MPa
- Output signal: (4 ~ 20) mA / HART
- Power: dual-wire (DC24V) four-wire (DC24V / AC220V)
- Measuring range: Liquid (0.5 ~ 15) m
- Process connection: Flange or swivelling holder
- PTFE 、 PU / PC
- Process temperature: (-40 ~ 70) ° C
- Process pressure: (-0.02 ~ 0.1) MPa
- Output signal: (4 ~ 20) mA / HART
- Power: dual-wire (DC24V) four-wire (DC24V / AC220V)
- Type: Magnetic level gauge
- Indicator system: Two-color flapper made of PBS plastic, 4 mm long and 0.25 mm thick with
- aligned magnets
- Fleet: SS316, SS316L, SS304, SS304L, PTFE, PVDF, PP, TITANIUM
- IP65, IP66, IP67
- SPDT, 230 VAC, 5 A or 24VDC, 0.5 A
- 4-20 m A