- Pressure range : -0,95 bar to 160 bar
- Media : Air
- Adjustment resolution: 1 KPa - 10 mbar
- Connections: 1/2,NPT F, 1/2 BSP F, or M20X1.5 F
- Ergonomics & user-friendly
- Robust design and reliable performance
- No specific maintenance required
- Delivered with a standard pressure gauge - ISO17025 Certificate (optional)
Calibration

Subcategories
Active filters
Stability: ± 0.02 °C
Resolution: 0.01 °C
Stabilization time: 7 minutes
Temperature unit: °C or °F selectable
Well diameter: 30 mm
Immersion length: 150 mm
Heating time: 10 minutes (Amb. to 120 °C)
Cooling time: 15 minutes (Amb. to (-) 10 °C)
25 minutes (120 °C to (-) 10 °C)
Communication port: RS232 port
Calibration software: MET-CAL as standard
Switch test: Provided
Power supply / Consumption: 110V to 240V AC, 50 to 60 Hz, 150 W
Dimensions (W x D x H) / Weight: 160 x 365 x 450 mm / 9 kg
Type of case: Portable
Carrying case: Provided
ISO17025 calibration certificate: Provided
- Generation and measurement of electrical signals
- Automatic switch test
- 24 V loop power supply
- RS-232 communication
- Data recording
- Documentation and automated procedures
- Generation and measurement of electrical signals
- Generation and measurement of temperatures
- Pulse frequency generation and measurement
- Automatic switch test
- 24 V loop power supply
- RS-232 communication
- Data recording
- Documentation and automated procedures
- Generation and measurement of electrical signals
- Generation and measurement of temperatures
- Pulse frequency generation and measurement
- Automatic switch test
- 24 V loop power supply
- RS-232 communication
- Data recording
- Documentation and automated procedures
- Intelligent pressure external modules
- Generation and measurement of electrical signals
- Generation and measurement of temperatures
- Pulse frequency generation and measurement
- Automatic switch test
- 24 V loop power supply
- RS-232 communication
- Data recording
- Documentation and automated procedures
- Communication Hart
- Intelligent pressure external modules
Température range : 50 °C ~ 650 °C
Accuracy: ± 0.3 °C
Stability: ± 0.02 °C
Resolution: 0.01 °C
Stabilization time: 7 minutes
Temperature unit: °C or °F selectable
Well diameter: 30 mm
Immersion length: 150 mm
Heating time: 10 minutes (Amb. to 120 °C)
Cooling time: 15 minutes (Amb. to (-) 10 °C)
25 minutes (120 °C to (-) 10 °C)
Communication port: RS232 port
Calibration software: MET-CAL as standard
Switch test: Provided
Power supply / Consumption: 110V to 240V AC, 50 to 60 Hz, 150 W
Dimensions (W x D x H) / Weight: 160 x 365 x 450 mm / 9 kg
Type of case: Portable
Carrying case: Provided
ISO17025 calibration certificate: Provided
- Easy to read Color Graphical TFT LCD display
- Rechargeable lithium ion battery with enhanced power control for prolonged battery life
- Measure or Source: mA, mV and V readings
- 24 VDC Loop power Supply to power transmitters and loops
- 2W simulate and Read/ Power mode for in-situ Loop checking and calibration
- Step/ Ramp functions with Auto/ Man selection
- Universal Serial Bus (USB) communication port for charging, data retrieve and firmware upgrade
- Data Logging to measure long time drift
- Other Features: Max/Min/Average, filter settings, tare facility, adjustable backlight, alarm annunciation (on display and buzzer), automatic Display off.
- Pressure range : 85% of vacuum up to 1000 bar
- Media : Oil
- Material : Body: SS & aluminum ~ Ram/adapters: SS ~ Seals: Buna-N
- Connections: 1/4NPT F, 1/4BSP F, or M20X1.5 F
- Dimensions: Base : 520×360 ~ Height ×230 (mm) 16 kg
- User-friendly, robust design and reliable performance
- Easy to read Color Graphical TFT LCD display
- Rechargeable lithium ion battery with enhanced power control for prolonged battery life
- Measure or Source: mA, mV and V readings
- 24 VDC Loop power Supply to power transmitters and loops
- 2W simulate and Read/ Power mode for in-situ Loop checking and calibration
- Step/ Ramp functions with Auto/ Man selection
- Universal Serial Bus (USB) communication port for charging, data retrieve and firmware upgrade
- Data Logging to measure long time drift
- Other Features: Max/Min/Average, filter settings, tare facility, adjustable backlight, alarm annunciation (on display and buzzer), automatic Display off.
- Pressure range : 85% of vacuum up to 700 bar
- Media : Oil and Water
- Material : Body: SS & aluminum ~ Ram/adapters: SS ~ Seals: Buna-N
- Connections: 1/4NPT F, 1/4BSP F, or M20X1.5 F
- Dimensions: Base : 290×198 ~ Height ×135 (mm) 3,2kg
- User-friendly, robust design and reliable performance
Accuracy: ± 0.3 °C
Stability: ± 0.05 °C
Resolution: 0.1 °C
Stabilization time: 7 minutes
Temperature unit: Selectable °C or °F
Well diameter: 19 mm
Immersion length: 100 mm
Heating time: 14 minutes (ambient to 123 °C)
Cooling time: 34 minutes (123 °C to (-)40 °C)
Interchangeable insert: Well for Ø 1/4’’ probes as standard (other sizes available on request).
Switch test: Provided
Power supply / Consumption: 100 V to 240V AC, 50 to 60 Hz, 150 W
Dimensions (L x W x H) / Weight: 160 x 365 x 350 mm / 9 kg
Enclosure type: Portable
- Direct Temperature output 12 Switched Steps
- < 0.3 °C Accuracy
- Quick Check Switch BOX
- Allows 2, 3 or 4 wire connections
- Compact Size
- Pressure range : 85% of vacuum up to 400 bar
- Media : Oil and Water
- Material : Body: SS & aluminum ~ Ram/adapters: SS ~ Seals: Buna-N
- Connections: 1/4NPT F, 1/4BSP F, or M20X1.5 F
- Dimensions: Base : 240×140 ~ Height ×120 (mm) 1,7kg
- User-friendly, robust design and reliable performance