- Communication : e-HART
- Output : 4 to 20mA
- Supply voltage : 7.5 to 45VDC
- Input : RTC, TC, Ohm, mV
- Cold junction : Internal
- Accuracy (Pt100) : <0,2K or 0,08%
- Influence of ambient : Negligible
- Load influence : Negligible
- Power supply influence : Negligible
- Resolution : 0.3uA
- Galvanic isolation (In/Out) : 2KVAC
- Installation : DIN Rail
Active filters
- Accuracy: ± 0.4% of full scaleUnits: kPa, Pa, PSI, Kg / cm², Bar, MPa
- Display: Large LCD screen with 5 DIGIT + Pressure graph
- Keys: On / Off, Reset, backlight
- Connection: 1/4 ’’ NPT, 1/4 ’’ G (or customizable)
- Dial size: 100 mm
- Max & min pressure recording
- Battery alarm function
- Ease of use, robust design and reliable performance
- Lithium battery 1 year autonomy in 24 hour operation
€186.00
Price
- Accuracy: ± 0.2% of full scale
- Units: kPa, Pa, PSI, Kg / cm², Bar, MPa
- Display: Large LCD screen with 5 DIGIT + Pressure graph
- Keys: On / Off, Reset, backlight
- Connection: 1/4 ’’ NPT, 1/4 ’’ G (or customizable)
- Dial size: 80 mm
- Max & min pressure recording
- Battery alarm function
- Ease of use, robust design and reliable performance
- Lithium battery 1 year autonomy in 24 hour operation
€234.00
Price
- Accuracy: ± 0.2% of full scale
- Units: kPa, Pa, PSI, Kg / cm², Bar, MPa
- Display: Large LCD screen with 5 DIGIT + Pressure graph
- Keys: On / Off, Reset, backlight
- Connection: 1/4 ’’ NPT, 1/4 ’’ G (or customizable)
- Dial size: 100 mm
- Max & min pressure recording
- Battery alarm function
- Ease of use, robust design and reliable performance
- Lithium battery 1 year autonomy in 24 hour operation
€246.00
Price
*Output: 4 to 20mA
*Supply voltage: 7.5 to 45VDC
*Input: RTD, TC, Ohm, mV
*Accuracy(Pt100): <0.2K or 0.08%
*Cold junction: Internal
*Galvanic isolation: 2 KVAC(In/Out)
*Influence of ambient: Negligible
*Load influence: Negligible
*Power supply influence: Negligible
*Resolution: 0.3uA
*Operation: HART-protocol
*Installation: sensor head Form B
*Dimensions: 44mm×24mm(Φ×H)
*Weight: approx. 35g
- 6 RTD inputs (2 & 3 files)
- PT100, Ni120, PT1000; Ni1000 -Din ...
- Modbus RTU compatible
- Insulation: 1500 Vrms
- Power supply: 12 V - 24 Vdc
- Up to 128 modules on the RS485 network
- Indication LEDs
- Rai-din fixing
- Module configuration software
- User Manual
€132.00
Price
- * Dimensions: 44mm×22.5mm(Φ×H)
- * Output: 4 to 20mA
- * Supply voltage: 11.5 to 35VDC (non-Ex-Area) 11.5 to 30VDC (Ex-Area)
- * Input: RTD, TC, Ohm, mV
- * Operation: HART-protocol
- * Galvanic isolation(In/Out): 2KVAC
- * Installation: sensor head Form B
- 8 Thermocouples inputs
- Modbus RTU compatible
- Type: J, K, E, T, N, B, S, R, mV, C, D & G
- Insulation: 1500 Vrms
- Power supply: 12 V - 24 Vdc
- Up to 128 modules on the RS485 network
- Indication LEDs
- Rai-din fixing
- Module configuration software
- User Manual
€348.00
Price
- 8 Current inputs
- Modbus RTU compatible
- Current: 0 - 20 mA
- Offset: 4 mA
- Insulation: 1500 Vrms
- Up to 128 modules on the RS485 network
- Indication LEDs
- Rai-din fixing
- Module configuration software
- User Manual
€324.00
Price
- 8 voltage inputs
- Modbus RTU compatible
- Voltage: 0 - 10 Vdc & 0 - 5 Vdc
- Offset: 2 Vdc [0-10] & 1 Vdc [1-5]
- Insulation: 1500 Vrms
- Up to 128 modules on the RS485 network
- Indication LEDs
- Rai-din fixing
- Module configuration software
- User Manual
€324.00
Price
- 8 current outputs
- Modbus RTU compatible
- Current: 0 - 20 mA
- Offset: 4 mA
- Insulation: 1500 Vrms
- Up to 128 modules on the RS485 network
- Indication LEDs
- Rai-din fixing
- Module configuration software
- User Manual
€348.00
Price
- 8 voltage outputs
- Modbus RTU compatible
- Voltage: 0 - 10 Vdc
- Offset: 2 Vdc
- Insulation: 1500 Vrms
- Up to 128 modules on the RS485 network
- Indication LEDs
- Rai-din fixing
- Module configuration software
- User Manual
€348.00
Price