Filter By

Categories

Categories

Availability

Availability

Weight

Weight

  • 7 kg - 17 kg

Price

Price

  • €0.00 - €11,112.00

Accueil

Active filters

  • Availability: Available
  • Weight: 7 kg - 17 kg

There are 21 products.

Filter By

Categories

Categories

Availability

Availability

Weight

Weight

  • 7 kg - 17 kg

Price

Price

  • €0.00 - €11,112.00

PPC-D Calibrateur de pression portable Pneumatique & Hydraulique ±0.025% PE
  • New
PPC-D Calibrateur de pression portable Pneumatique &...

  • Pneumatic Pressure: -0.85 to 20 bar.
  • Hydraulic Pressure: 0 to 400 bar.
  • Accuracy: ±0.025% FS.
  • Temperature Compensation: Automatic from 0 to 50 °C.
  • Selectable Pressure Units: kg/cm², psi, bar, mbar, etc.
  • Current Input: 50 mA active, 25 mA passive, 800 Ω resistance.
  • Voltage Input: 0 to 30 VDC, resolution 0.01 (mA/V).
  • Switch Test: Up to 5 VDC.
  • Media: Air and oil.
  • Overpressure Alarm: 120% FS (visual and audible).
  • Pressure Generation: Built-in pumps with fine adjustment vernier.
  • Power Supply: Rechargeable 7.2 Volts (AA) battery.
  • Operating Temperature: 15 °C to 40 °C.
  • Storage Temperature Range: 10 °C to 60 °C.
  • Protection Class: IP10.
  • Zero Adjustment: Automatic if pressure is less than 1% FS.
PPC-D+ Calibrateur de pression portable Pneumatique & Hydraulique ±0.025% PE
  • New
PPC-D+ Calibrateur de pression portable Pneumatique &...
Pneumatic Pressure: -0.85 to 20 bar.
Hydraulic Pressure: 0 to 400 bar.
Accuracy: ±0.025% FS.
Temperature Compensation: Automatic from 0 to 50 °C.
Selectable Pressure Units: kg/cm², psi, bar, mbar, etc.
Current Input: 50 mA active, 25 mA passive, 800 Ω resistance.
Voltage Input: 0 to 30 VDC, resolution 0.01 (mA/V).
Switch Test: Up to 5 VDC.
Media: Air and oil.
Overpressure Alarm: 120% FS (visual and audible).
Pressure Generation: Built-in pumps with fine adjustment vernier.
Power Supply: Rechargeable 7.2 Volts (AA) battery.
Operating Temperature: 15 °C to 40 °C.
Storage Temperature Range: 10 °C to 60 °C.
Protection Class: IP10.
Zero Adjustment: Automatic if pressure is less than 1% FS.
DUS-D-V Portable Doppler Ultrasonic Flow Meter
  • New
DUS-D-V Portable Doppler Ultrasonic Flow Meter
  • For wastewater and two-phase liquids (emulsion)
  • Non-intrusive transducers from DN40 to DN4000
  • Suitable for all types of pipes (uni-material)
  • Transducers -35 ~ 85 ° C
  • 5 m cables
  • Excellent measurement capacity for low flow rates (from 0.05m / s)
  • Easy installation & configuration
  • Outputs: 4-20mA as standard
  • Accuracy: 0.5% to 2.0%
  • Battery: Autonomy 40 h
€3,650.00
UltraFroid-100C Température Ambiante (-)100 °C à +25 °C
  • New
UltraFroid-100C Température Ambiante (-)100 °C à +25 °C

  • Temperature range: -100°C to +25°C
  • Accuracy: ± 0.3 °C
  • Stability: ± 0.05 °C
  • Resolution:Stabilization time: 15 minutes
    • 0.01°C (from +25 to +19.99°C)
    • 0.1°C (from 20°C to -100°C)
  • Temperature unit: Selectable °C or °F
  • Well diameter: 30 mm
  • Immersion length: 150 mm
  • Heating time: 50 minutes (from ambient to maximum)
  • Cooling time:Switch test: Provided
    • 40 minutes (from +25°C to -60°C)
    • 50 minutes (from -60°C to -100°C)
  • Power supply / Consumption: 90 ~ 220 V AC, 50/60 Hz
  • Dimensions (L x P x H) : 439 x 240 x 358 mm
  • Weight: 15 kg
  • Calibration certificate: Factory traceable to ISO17025 included or ISO17025 certificate from an accredited lab

ADT-919A Pneumatic Pressure Test Pump 140 bar
  • New
ADT-919A Pneumatic Pressure Test Pump 140 bar
  • Pressure range : 95% of vacuum up to 140 bar 
  • Media : Air
  • Adjustment resolution: 0,1 mbar
  • Material : Body: SS & aluminum ~ Ram/adapters: SS ~ Seals: Buna-N
  • Connections: 1/4NPT F, 1/4BSP F, or M20X1.5 F
  • Dimensions: Base : 540×270 ~ Height ×178 (mm) 6.5 kg
  • User-friendly, robust design and reliable performance
ADT-920 Pneumatic Pressure Test Pump 200 bar
  • New
ADT-920 Pneumatic Pressure Test Pump 200 bar
  • Pressure range : 95% of vacuum up to 200 bar 
  • Media : Air
  • Adjustment resolution: 0,1 mbar
  • Material : Body: SS & aluminum ~ Ram/adapters: SS ~ Seals: Buna-N
  • Connections: 1/4NPT F, 1/4BSP F, or M20X1.5 F
  • Dimensions: Base : 540×270 ~ Height ×178 (mm) 6,5 kg
  • User-friendly, robust design and reliable performance
CN-BT Blackbody Calibration Furnace Tem. Ambient +10°C to 300°C
  • New
CN-BT Blackbody Calibration Furnace Tem. Ambient +10°C to 300°C

CN-BT (Low Temperature):

  • Temperature Range: Ambient Temp. +10 °C to 350 °C
  • Accuracy: Less than 0.5% F.S. (Min. 1 °C)
  • Stability: ± 0.5 °C
  • Resolution: 0.1 °C
  • Emissivity: 0.98
  • Aperture Diameter: 25 mm
  • Time to Reach Max Temperature: 45 minutes
  • Stabilization Time: 20 minutes (above 75 °C)
  • Dimensions (L x W x H) / Weight: 485 x 430 x 190 mm / 11 kg
  • Calibration Certification: Factory with ISO17025 traceability included


CALMET-40 Calibration oven ambient temperature (-)10°C to 120°C
  • New
CALMET-40 Calibration oven ambient temperature (-)10°C to 120°C
Temperature range: (-)10°C ~120°C
Accuracy: ± 0.3 °C
Stability: ± 0.02 °C
Resolution: 0.01 °C
Stabilization time: 7 minutes
Temperature unit: °C or °F selectable
Well diameter: 30 mm
Immersion length: 150 mm
Heating time: 10 minutes (Amb. to 120 °C)
Cooling time: 15 minutes (Amb. to (-) 10 °C)
                    25 minutes (120 °C to (-) 10 °C)
Communication port: RS232 port
Calibration software: MET-CAL as standard
Switch test: Provided
Power supply / Consumption: 110V to 240V AC, 50 to 60 Hz, 150 W
Dimensions (W x D x H) / Weight: 160 x 365 x 450 mm / 9 kg
Type of case: Portable
Carrying case: Provided
ISO17025 calibration certificate: Provided
ADT-936 Hydraulic Pressure Test Pump 1000 bar
  • New
ADT-936 Hydraulic Pressure Test Pump 1000 bar
  • Pressure range : 85% of vacuum up to 1000 bar 
  • Media : Oil
  • Material : Body: SS & aluminum ~ Ram/adapters: SS ~ Seals: Buna-N
  • Connections: 1/4NPT F, 1/4BSP F, or M20X1.5 F
  • Dimensions: Base : 520×360 ~ Height ×230 (mm) 16 kg
  • User-friendly, robust design and reliable performance
CN-HT Blackbody Calibration Oven 500 °C to 1200 °C
  • New
CN-HT Blackbody Calibration Oven 500 °C to 1200 °C

CN-HT (High Temperature):

  • Temperature Range: 500 °C to 1200 °C
  • Accuracy: Less than 0.5% F.S. (Min. 3 °C)
  • Stability: ± 0.5 °C
  • Resolution: 1 °C
  • Emissivity: 0.98
  • Aperture Diameter: 25 mm
  • Time to Reach Max Temperature: 60 minutes
  • Stabilization Time: 20 minutes (above 75 °C)
  • Dimensions (L x W x H) / Weight: 485 x 430 x 190 mm / 11 kg
  • Calibration Certification: Factory with ISO17025 traceability included

CALMET-650 Calibration oven 50°C ~ 650°C
  • New
CALMET-650 Calibration oven 50°C ~ 650°C

Température range : 50 °C ~ 650 °C
Accuracy: ± 0.3 °C
Stability: ± 0.02 °C
Resolution: 0.01 °C
Stabilization time: 7 minutes
Temperature unit: °C or °F selectable
Well diameter: 30 mm
Immersion length: 150 mm
Heating time: 10 minutes (Amb. to 120 °C)
Cooling time: 15 minutes (Amb. to (-) 10 °C)
                    25 minutes (120 °C to (-) 10 °C)
Communication port: RS232 port
Calibration software: MET-CAL as standard
Switch test: Provided
Power supply / Consumption: 110V to 240V AC, 50 to 60 Hz, 150 W
Dimensions (W x D x H) / Weight: 160 x 365 x 450 mm / 9 kg
Type of case: Portable
Carrying case: Provided
ISO17025 calibration certificate: Provided

CN-MT Blackbody Calibration Oven 250 °C to 600 °C
  • New
CN-MT Blackbody Calibration Oven 250 °C to 600 °C

CN-BT (Low Temperature):

  • Temperature Range: Ambient Temp. +10 °C to 350 °C
  • Accuracy: Less than 0.5% F.S. (Min. 1 °C)
  • Stability: ± 0.5 °C
  • Resolution: 0.1 °C
  • Emissivity: 0.98
  • Aperture Diameter: 25 mm
  • Time to Reach Max Temperature: 45 minutes
  • Stabilization Time: 20 minutes (above 75 °C)
  • Dimensions (L x W x H) / Weight: 485 x 430 x 190 mm / 11 kg
  • Calibration Certification: Factory with ISO17025 traceability included

CALMET-1200 Calibration oven 300 °C ~ 1200 °C
  • New
CALMET-1200 Calibration oven 300 °C ~ 1200 °C
Température range: 50 °C ~ 650 °C 300 °C ~ 1200 °C
Accuracy: ± 2 °C
Stability: ± 0.3 °C
Resolution: 0.1 °C
Stabilization time: 15 minutes
Temperature unit: Selectable °C or °F
Well diameter: 30 mm
Immersion length: 105 mm
Heating time: 30 minutes (100 °C to 800 °C)
Cooling time: 120 minutes (800 °C to 200 °C)
Communication port: Standard RS232 port
Calibration software: Standard MET-CAL software included
Switch test: Provided
Power supply / Consumption: 230V AC, 50 Hz & 115V AC switchable, 60 Hz
Dimensions (L x W x H) / Weight: 160 x 365 x 450 mm / 11 kg
Enclosure type: Portable
Carrying case: Included
ISO17025 calibration certificate: Included
copy of CN-HT Blackbody Calibration Oven 500 °C to 1200 °C
  • New
copy of CN-HT Blackbody Calibration Oven 500 °C to 1200 °C

CN-DT (Duo – Dual Cavities):

  • Cavity 1: +50 °C to 300 °C
  • Cavity 2: +250 °C to 600 °C
  • Accuracy: Less than 0.5% F.S. (Cavity 1 Min. 1 °C / Cavity 2 Min. 2 °C)
  • Stability: ± 0.5 °C
  • Resolution: 1 °C
  • Emissivity: 0.98
  • Aperture Diameter: 25 mm
  • Time to Reach Max Temperature: 45 minutes
  • Stabilization Time: 30 minutes (above 75 °C)
  • Dimensions (L x W x H) / Weight: 450 x 410 x 190 mm / 14 kg
  • Calibration Certification: Factory with ISO17025 traceability included

CTM-40 Calibration oven ambient temperature (-)40°C to 123°C
  • New
CTM-40 Calibration oven ambient temperature (-)40°C to 123°C

Accuracy: ± 0.3 °C
Stability: ± 0.05 °C
Resolution: 0.1 °C
Stabilization time: 7 minutes
Temperature unit: Selectable °C or °F
Well diameter: 19 mm
Immersion length: 100 mm
Heating time: 14 minutes (ambient to 123 °C)
Cooling time: 34 minutes (123 °C to (-)40 °C)
Interchangeable insert: Well for Ø 1/4’’ probes as standard (other sizes available on request).
Switch test: Provided
Power supply / Consumption: 100 V to 240V AC, 50 to 60 Hz, 150 W
Dimensions (L x W x H) / Weight: 160 x 365 x 350 mm / 9 kg
Enclosure type: Portable