Active filters
-
Categories:
Automation
-
Categories:
LEVEL
-
Categories:
Pressure
PI305X-TSD Absolute pressure transmitter
- Measuring range: 2kPa-10MPa
- Output signal: 4-20mA, 4 ~ 20mA / HART, client
- Reference accuracy: ± 0.15% URL, optional ± 0.1% URL
- Operating temperature: -40-85, LCD display: -20-70 ℃
- Fluid temperature: -40-120
- Measuring fluid: level, density and pressure of the liquid, gas or vapor
- Protection class: IP67
- Diaphragm material: SUS316L, Hastelloy C
- Stability: ± 0.2% URL / 60 months
- Process connection: M20 * 1.5 (M), 1 / 2-14NPT (F), 1 / 4-18NPT (F)
- Approvals: ATEX, IECEx, NEPSI, RoHS, CE
PI305-FSD Absolute pressure transmitter
- Measuring range: 200Pa-10MPa
- Output signal: 4-20mA, 4 ~ 20mA / HART, client
- Reference accuracy: ± 0.15% URL, optional ± 0.1% URL
- Fluid temperature: -40-120
- Measuring fluid: level, density and pressure of the liquid, gas or vapor
- Protection class: IP67
- Diaphragm material: SUS316L, Hastelloy C
- Stability: ± 0.2% URL / 60 months
- Process connection: M20 * 1.5 (M), 1 / 2-14NPT (F), 1 / 4-18NPT (F)
- Approvals: ATEX, MC, NEPSI, CE
IO-16DO Module 16 Digital Outputs
- 16 digital outputs
- Modbus RTU compatible
- Insulation: 1500 Vrms
- Indication LEDs for each channel
- Power supply: 12 V - 24 Vdc
- Up to 128 modules on the RS485 network
- Indication LEDs
- Rai-din fixing
- Module configuration software
- User Manual
PI131-DST-S compact pressure transmitter
- Measuring range : 2 kPa at 40 MPa (20 mBar at 40 bar)
- Output signal: 4-20mA, 4-20mA + HART, 0-5 VDC, Modbus-RTU / RS485, others
- Accuracy: ± 0.1% URL, optional ± 0.075% URL
- Process connection: M20 * 1.5, 1/2 "G, 1/4" G, 1/2 "NPT or 1/4" NPT
- Measuring medium: liquid, gas or vapor
- Fluid temperature: -30 to 80 ° C
- Electrical connection: DIN43650 IP65 or M12 * 1 (4 pins) IP67
PI858-DST-S Compact sanitary pressure transmitter
- Measuring range: 10kPa-3MPa
- Output signal: 4-20mA, 4-20mA + HART, 0.5-4.5VDC, Modbus-RTU / RS485 ...
- Accuracy: ± 0.2% URL, ± 0.5% URL
- Fluid temperature: -40 to 120 ° C
- Measurement: pressure, level, differential pressure, density, flow
- Protection class: IP67
- Diaphragm material: SUS316L, Hastelloy C
- Stability: ± 0.2% of URL / 1 year
- Process connection: Tri-Clamp 1-1 / 2 ", Tri-Clamp 2", DIN32676 DN32, ISO2852, DRD
- Certificates: 3A, EHEDG, CE, RoHS, Ex-proof
PI-PH6.0 PH Meter
- Measure range: pH: 0-14 pH, ±0.02pH;
- ORP: -1000 ~1000mV, ±1mV
- Input Resistance: ≥10~12Ω
- Temperature compensation : Manual/ Auto temperature compensation
- Signal output : 4-20mA, maximum loop 750Ω, 0.2%FS
- Communication : RS485 Modbus-RTU
- Relay output : 250V, 3A
- Power supply: 220V±10%,50Hz/60Hz
PI858-FST-H Flush diaphragm sanitary pressure transmitter
- Type of pressure: relative pressure
- Measuring range: 10kPa-10MPa
- Output signal: 4-20mA, 4-20mA + HART
- Accuracy: ± 0.2% of URL, ± 0.5% of URL
- Process connection: Tri-Clamp 1-1 / 2 ", Tri-Clamp 2", DIN32676 DN32, ISO2852, DRD ...
- Certificates: 3A, EHEDG, CE, RoHS, Ex-proof certificate
PI858-FST-S Flush diaphragm sanitary pressure transmitter
- Type of pressure: pressure retaive
- Measuring range: 10kPa-3MPa
- Output signal: 4-20mA, 4-20mA + HART
- Reference accuracy: ± 0.2% of URL, ± 0.5% of URL
- Process connection: Tri-Clamp 1-1 / 2 ", Tri-Clamp 2", DIN32676 DN32, ISO2852, DRD ...
- Approvals: 3A, EHEDG, CE, RoHS, Ex-proof certificate
PRCAL 518 Intelligent Process Calibrator
- Generation and measurement of electrical signals
- Generation and measurement of temperatures
- Pulse frequency generation and measurement
- Automatic switch test
- 24 V loop power supply
- RS-232 communication
- Data recording
- Documentation and automated procedures
- Communication Hart
- Intelligent pressure external modules
PRCAL 517 Multifunction process calibrator
- Generation and measurement of electrical signals
- Generation and measurement of temperatures
- Pulse frequency generation and measurement
- Automatic switch test
- 24 V loop power supply
- RS-232 communication
- Data recording
- Documentation and automated procedures
- Intelligent pressure external modules
PMP-25 Pneumatic Test Pump -0.95 to 25 bar
- Pressure range: 95% of vacuum to 25 bar
- Media: Air
- Resolution: 1 mbar
- Material: Body: Stainless steel & aluminum ~ Fittings: Stainless steel ~ Gaskets: Buna-N
- Instrument connections: 1 / 4NPT F, 1 / 4BSP F, or M20X1.5 F
- Dimensions: Base: 280 × 170 ~ Height × 140 (mm) 2.4 kg
- Ease of use, robust design and reliable performance
PMP-40 Pneumatic Test Pump -0.95 à 40 bar
- Pressure range : 95% of vaccum up to 40 bar
- Media : Air
- Adjustement resolution: 1 mbar
- Material : Body: SS & aluminum ~ Ram/adapters: SS ~ Seals: Buna-N
- Connections: 1/4NPT F, 1/4BSP F, or M20X1.5 F
- Dimensions: Base : 280 ×170 ~ Height ×140 (mm) 2.4 kg
- User-friendly, robust design and reliable performance
PI-TDS210-C Conductivity Meter
Features
- Range: 0.01 electrode: 0.02~20.00us/cm
- 0.1 electrode: 0.2~200.0us/cm
- 1.0 electrode: 2~2000us/cm
- 10.0 electrode: 0.02~20ms/cm
- Output signal: 4 ~ 20 mA; Relay; RS485
- Power supply: AC220V±10%, 50Hz/60Hz
- Operating temperature: 0~60°C
- Accuracy : ± 2 % PE
- Measuring medium: Liquid
- Relay output: 250 VAC, 3A
ADT-901 Pneumatic Test Pump -0.4 up tp 0.4 bar
- Pressure range : -0,4 up to 0,4 bar
- Media : Air
- Adjustment resolution: 0,001 mbar
- Material : Body: SS & aluminum ~ Ram/adapters: SS ~ Seals: Buna-N
- Connections: 1/4NPT F, 1/4BSP F, or M20X1.5 F
- Dimensions: Base : 240×130 ~ Height ×130 (mm) 1.5 kg
- User-friendly, robust design and reliable performance
PI-DM2800 Membrane dissolved oxygen meter
- Range: 0-20 mg/L, 0-200%, 0-400 hPa
- Resolution: 0.01 mg/L, 0.1%, 1 hPa
- Output signal: 4 ~ 20 mA; Relay; RS485
- Power supply: AC220V±10%; 50Hz/60Hz
- Communication protocol: MODBUS-RTU standard (customizable)
- Operating temperature: 0~60 °C