- Accuracy ± 0.2%
- RS485 modbus
- 8 Relays at Maximum output
- Sampling cycle 1 second
- 24V power supply output
- Voltage: 220VAC or 24VDC
- 2 types of display: fixed and circular channel
Active filters
€1,140.00
Price
*Output: 4 to 20mA
*Supply voltage: 7.5 to 45VDC
*Input: RTD, TC, Ohm, mV
*Accuracy(Pt100): <0.2K or 0.08%
*Cold junction: Internal
*Galvanic isolation: 2 KVAC(In/Out)
*Influence of ambient: Negligible
*Load influence: Negligible
*Power supply influence: Negligible
*Resolution: 0.3uA
*Operation: HART-protocol
*Installation: sensor head Form B
*Dimensions: 44mm×24mm(Φ×H)
*Weight: approx. 35g
- 3.5 "TFT LCD screen (320 x 240)
- RS485 modbus
- 24V power supply output
- USB port
- Multiple display
- Calendar search functions by date and time
- Review historical data
€630.00
Price
- Dimensions: 44mm×22.5mm(Φ×H)
- Output: 4 to 20mA
- Supply voltage: 8 to 35VDC (non-Ex-Area)
- 8 to 30VDC (Ex-Area)
- Input: PT100
- Installation: sensor head Form B
- 6 universal channels
- 0.2% accuracy
- Printing: 6 colors
- Dustproof, IP-65 waterproof
- RS-232 communication interface
- Universal entrance and range
- UL, CSA, CE compliance
- 144 (L) x144 (H) x150 (D) mm Weight 1.54 kg
- 1 pack of print sheet
- 1 ink ribbon
€1,548.00
Price
- * Galvanic isolation
- * No external power supply for configuration
- * Write or read the configuration off-line by just connecting a PC
- * Fault signal on sensor break or short circuit
- * 2 wire technology, 4 to 20mA analogue output
- * High accuracy in total ambient temperature range
- * Customer specific measurement range setting or expanded SETUP
- 6 RTD inputs (2 & 3 files)
- PT100, Ni120, PT1000; Ni1000 -Din ...
- Modbus RTU compatible
- Insulation: 1500 Vrms
- Power supply: 12 V - 24 Vdc
- Up to 128 modules on the RS485 network
- Indication LEDs
- Rai-din fixing
- Module configuration software
- User Manual
€132.00
Price
- * Dimensions: 44mm×22.5mm(Φ×H)
- * Output: 4 to 20mA
- * Supply voltage: 11.5 to 35VDC (non-Ex-Area) 11.5 to 30VDC (Ex-Area)
- * Input: RTD, TC, Ohm, mV
- * Operation: HART-protocol
- * Galvanic isolation(In/Out): 2KVAC
- * Installation: sensor head Form B
- 8 isolated Thermocouples inputs
- Modbus RTU compatible
- Type: J, K, E, T, N, B, S, R, mV, C, D & G
- Insulation: 1500 Vrms (350 V between channels)
- Power supply: 12 V - 24 Vdc
- Up to 128 modules on the RS485 network
- Indication LEDs
- Rai-din fixing
- Module configuration software
- User Manual
€456.00
Price
- 8 Thermocouples inputs
- Modbus RTU compatible
- Type: J, K, E, T, N, B, S, R, mV, C, D & G
- Insulation: 1500 Vrms
- Power supply: 12 V - 24 Vdc
- Up to 128 modules on the RS485 network
- Indication LEDs
- Rai-din fixing
- Module configuration software
- User Manual
€348.00
Price
- 8 Current inputs
- Modbus RTU compatible
- Current: 0 - 20 mA
- Offset: 4 mA
- Insulation: 1500 Vrms
- Up to 128 modules on the RS485 network
- Indication LEDs
- Rai-din fixing
- Module configuration software
- User Manual
€324.00
Price
- 8 current differential inputs
- Modbus RTU compatible
- Current: 0 - 20 mA
- Offset: 4 mA
- Insulation: 1000 Vrms (350 V between channels)
- Up to 128 modules on the RS485 network
- Indication LEDs
- Rai-din fixing
- Module configuration software
- User Manual
€456.00
Price