Active filters
-
Categories:
Automation
-
Categories:
Temperature
PITMT181L - Temperature transmitter
- * Galvanic isolation
- * No external power supply for configuration
- * Write or read the configuration off-line by just connecting a PC
- * Fault signal on sensor break or short circuit
- * 2 wire technology, 4 to 20mA analogue output
- * High accuracy in total ambient temperature range
- * Customer specific measurement range setting or expanded SETUP
CR06 Universal 6 Way Paper Recorder
- 6 universal channels
- 0.2% accuracy
- Printing: 6 colors
- Dustproof, IP-65 waterproof
- RS-232 communication interface
- Universal entrance and range
- UL, CSA, CE compliance
- 144 (L) x144 (H) x150 (D) mm Weight 1.54 kg
- 1 pack of print sheet
- 1 ink ribbon
PITMT182L - Temperature transmitter
- * Dimensions: 44mm×22.5mm(Φ×H)
- * Output: 4 to 20mA
- * Supply voltage: 11.5 to 35VDC (non-Ex-Area) 11.5 to 30VDC (Ex-Area)
- * Input: RTD, TC, Ohm, mV
- * Operation: HART-protocol
- * Galvanic isolation(In/Out): 2KVAC
- * Installation: sensor head Form B
IO-8TCS Thermocouple Isolated Analog Input Module
- 8 isolated Thermocouples inputs
- Modbus RTU compatible
- Type: J, K, E, T, N, B, S, R, mV, C, D & G
- Insulation: 1500 Vrms (350 V between channels)
- Power supply: 12 V - 24 Vdc
- Up to 128 modules on the RS485 network
- Indication LEDs
- Rai-din fixing
- Module configuration software
- User Manual
IO-8TC Analog Thermocouple Input Module
- 8 Thermocouples inputs
- Modbus RTU compatible
- Type: J, K, E, T, N, B, S, R, mV, C, D & G
- Insulation: 1500 Vrms
- Power supply: 12 V - 24 Vdc
- Up to 128 modules on the RS485 network
- Indication LEDs
- Rai-din fixing
- Module configuration software
- User Manual
IO-8AIIS Current Differential Analog Input Module
- 8 current differential inputs
- Modbus RTU compatible
- Current: 0 - 20 mA
- Offset: 4 mA
- Insulation: 1000 Vrms (350 V between channels)
- Up to 128 modules on the RS485 network
- Indication LEDs
- Rai-din fixing
- Module configuration software
- User Manual
IO-8AIV Analog Voltage Input Module
- 8 voltage inputs
- Modbus RTU compatible
- Voltage: 0 - 10 Vdc & 0 - 5 Vdc
- Offset: 2 Vdc [0-10] & 1 Vdc [1-5]
- Insulation: 1500 Vrms
- Up to 128 modules on the RS485 network
- Indication LEDs
- Rai-din fixing
- Module configuration software
- User Manual
IO-8AIVS Isolated Analog Voltage Input Module
- 8 isolated voltage inputs
- Modbus RTU compatible
- Voltage: 0 - 10 Vdc & 0 - 5 Vdc
- Offset: 2 Vdc [0-10] & 1 Vdc [1-5]
- Insulation: 1500 Vrms (350 V between channels)
- Up to 128 modules on the RS485 network
- Indication LEDs
- Rai-din fixing
- Module configuration software
- User Manual
IO-8AOI Current Analog Output Module
- 8 current outputs
- Modbus RTU compatible
- Current: 0 - 20 mA
- Offset: 4 mA
- Insulation: 1500 Vrms
- Up to 128 modules on the RS485 network
- Indication LEDs
- Rai-din fixing
- Module configuration software
- User Manual
IO-8AOV Analog Voltage Output Module
- 8 voltage outputs
- Modbus RTU compatible
- Voltage: 0 - 10 Vdc
- Offset: 2 Vdc
- Insulation: 1500 Vrms
- Up to 128 modules on the RS485 network
- Indication LEDs
- Rai-din fixing
- Module configuration software
- User Manual
IO-DAIO Analog & Digital Combination Module
- 2 inputs & 1 analog output
- 4 digital inputs & 2 digital outputs
- 2 RTD inputs
- Modbus RTU compatible
- Up to 128 modules on the RS485 network
- Indication LEDs
- Rai-din fixing
- Module configuration software
- User Manual
IO-16DO Module 16 Digital Outputs
- 16 digital outputs
- Modbus RTU compatible
- Insulation: 1500 Vrms
- Indication LEDs for each channel
- Power supply: 12 V - 24 Vdc
- Up to 128 modules on the RS485 network
- Indication LEDs
- Rai-din fixing
- Module configuration software
- User Manual
PI-PH6.0 PH Meter
- Measure range: pH: 0-14 pH, ±0.02pH;
- ORP: -1000 ~1000mV, ±1mV
- Input Resistance: ≥10~12Ω
- Temperature compensation : Manual/ Auto temperature compensation
- Signal output : 4-20mA, maximum loop 750Ω, 0.2%FS
- Communication : RS485 Modbus-RTU
- Relay output : 250V, 3A
- Power supply: 220V±10%,50Hz/60Hz
PI-TDS210-C Conductivity Meter
Features
- Range: 0.01 electrode: 0.02~20.00us/cm
- 0.1 electrode: 0.2~200.0us/cm
- 1.0 electrode: 2~2000us/cm
- 10.0 electrode: 0.02~20ms/cm
- Output signal: 4 ~ 20 mA; Relay; RS485
- Power supply: AC220V±10%, 50Hz/60Hz
- Operating temperature: 0~60°C
- Accuracy : ± 2 % PE
- Measuring medium: Liquid
- Relay output: 250 VAC, 3A
PI-DM2800 Membrane dissolved oxygen meter
- Range: 0-20 mg/L, 0-200%, 0-400 hPa
- Resolution: 0.01 mg/L, 0.1%, 1 hPa
- Output signal: 4 ~ 20 mA; Relay; RS485
- Power supply: AC220V±10%; 50Hz/60Hz
- Communication protocol: MODBUS-RTU standard (customizable)
- Operating temperature: 0~60 °C