Theme Features - you can manage from admin

Select Theme
Custome Color 1
Custome Color 2
Box-Layout
Background Pattern

Custome background also available in admin.

Background color
Wow Animation Enable
Slider 3D Animation Enable
Menu Sticky Enable
Bottom Option Enable
Accueil
Accueil
Grid
List

There are 21 products.

Grid
List
Showing 13-21 of 21 item(s)
Active filters
  • Categories: Flow
  • Categories: Calibration
  • Price: €0.00 - €1.00
  • Integrated pneumatic pressure pump up to 70 bar
  • Pressure module: any scale from -0.95 to 70 bar
  • Accuracy: 0.01 % of full scale
  • Temperature compensation up to 50 °C 
  • High stability & accuracy 
  • Simulates & measures electrical signals
  • 4.3 " TFT colour touch screen
  • 8 hours battery life
  • USB PC interface & Calibration software 
  • ISO17025 traceable calibration certificate

Temperature range: (-)10°C ~120°C
Accuracy: ± 0.3 °C
Stability: ± 0.02 °C
Resolution: 0.01 °C
Stabilization time: 7 minutes
Temperature unit: °C or °F selectable
Well diameter: 30 mm
Immersion length: 150 mm
Heating time: 10 minutes (Amb. to 120 °C)
Cooling time: 15 minutes (Amb. to (-) 10 °C)
                    25 minutes (120 °C to (-) 10 °C)
Communication port: RS232 port
Calibration software: MET-CAL as standard
Switch test: Provided
Power supply / Consumption: 110V to 240V AC, 50 to 60 Hz, 150 W
Dimensions (W x D x H) / Weight: 160 x 365 x 450 mm / 9 kg
Type of case: Portable
Carrying case: Provided
ISO17025 calibration certificate: Provided

Température range : 50 °C ~ 650 °C
Accuracy: ± 0.3 °C
Stability: ± 0.02 °C
Resolution: 0.01 °C
Stabilization time: 7 minutes
Temperature unit: °C or °F selectable
Well diameter: 30 mm
Immersion length: 150 mm
Heating time: 10 minutes (Amb. to 120 °C)
Cooling time: 15 minutes (Amb. to (-) 10 °C)
                    25 minutes (120 °C to (-) 10 °C)
Communication port: RS232 port
Calibration software: MET-CAL as standard
Switch test: Provided
Power supply / Consumption: 110V to 240V AC, 50 to 60 Hz, 150 W
Dimensions (W x D x H) / Weight: 160 x 365 x 450 mm / 9 kg
Type of case: Portable
Carrying case: Provided
ISO17025 calibration certificate: Provided

Température range: 50 °C ~ 650 °C 300 °C ~ 1200 °C
Accuracy: ± 2 °C
Stability: ± 0.3 °C
Resolution: 0.1 °C
Stabilization time: 15 minutes
Temperature unit: Selectable °C or °F
Well diameter: 30 mm
Immersion length: 105 mm
Heating time: 30 minutes (100 °C to 800 °C)
Cooling time: 120 minutes (800 °C to 200 °C)
Communication port: Standard RS232 port
Calibration software: Standard MET-CAL software included
Switch test: Provided
Power supply / Consumption: 230V AC, 50 Hz & 115V AC switchable, 60 Hz
Dimensions (L x W x H) / Weight: 160 x 365 x 450 mm / 11 kg
Enclosure type: Portable
Carrying case: Included
ISO17025 calibration certificate: Included

Accuracy: ± 0.3 °C
Stability: ± 0.05 °C
Resolution: 0.1 °C
Stabilization time: 7 minutes
Temperature unit: Selectable °C or °F
Well diameter: 19 mm
Immersion length: 100 mm
Heating time: 14 minutes (ambient to 123 °C)
Cooling time: 34 minutes (123 °C to (-)40 °C)
Interchangeable insert: Well for Ø 1/4’’ probes as standard (other sizes available on request).
Switch test: Provided
Power supply / Consumption: 100 V to 240V AC, 50 to 60 Hz, 150 W
Dimensions (L x W x H) / Weight: 160 x 365 x 350 mm / 9 kg
Enclosure type: Portable

Plage de température : 50 °C ~ 350 °C
Accuracy: ± 0.4 °C
Stability: ± 0.05 °C
Resolution: 0.1 °C
Stabilization time: 20 minutes
Temperature unit: Selectable °C or °F
Well diameter: 25 mm
Immersion length: 110 mm
Heating time: 20 minutes (ambient to 350 °C)
Cooling time: 33 minutes (350 °C to ambient temperature)
Interchangeable insert: Well for Ø 1/4’’ and 1/2’’ probes as standard (other sizes available on request).
Switch test: Provided
Power supply / Consumption: 230 V AC, 50 Hz, 520 W
Dimensions (L x W x H) / Weight: 160 x 365 x 350 mm / 9 kg
Enclosure type: Portable
Température range : 50 °C ~ 650 °C
Accuracy: ± 0.6 °C
Stability: ± 0.05 °C
Resolution: 0.1 °C
Stabilization time: 20 minutes
Temperature unit: Selectable °C or °F
Well diameter: 25 mm
Immersion length: 110 mm
Heating time: 20 minutes (ambient to 650 °C)
Cooling time: 42 minutes (650 °C to ambient temperature)
Interchangeable insert: Well for Ø 1/4’’ and 1/2’’ probes as standard (other sizes available on request).
Switch test: Provided
Power supply / Consumption: 230 V AC, 50 Hz, 1230 W
Dimensions (L x W x H) / Weight: 160 x 365 x 350 mm / 11 kg
Enclosure type: Portable
Temperature range: 300 °C ~ 1200 °C
Accuracy: ± 2 °C
Stability: ± 0.5 °C
Resolution: 1 °C
Stabilization time: 20 minutes
Temperature unit: Selectable °C or °F
Well diameter: 26 mm
Immersion length: 105 mm
Heating time: 60 minutes (ambient to 1200 °C)
Cooling time: 45 minutes (1200 °C to ambient temperature)
Interchangeable insert: Well for Ø 1/4’’ and 1/2’’ probes as standard (other sizes available on request).
Switch test: Provided
Power supply / Consumption: 230 V AC, 50 Hz / 115 V AC, 60 Hz, 650 W, switchable
Dimensions (L x W x H) / Weight: 160 x 365 x 350 mm / 9 kg
Enclosure type: Portable