Active filters
-
Categories:
Liquid analysis
-
Categories:
Recorder
PI-PH6.0 PH Meter
- Measure range: pH: 0-14 pH, ±0.02pH;
- ORP: -1000 ~1000mV, ±1mV
- Input Resistance: ≥10~12Ω
- Temperature compensation : Manual/ Auto temperature compensation
- Signal output : 4-20mA, maximum loop 750Ω, 0.2%FS
- Communication : RS485 Modbus-RTU
- Relay output : 250V, 3A
- Power supply: 220V±10%,50Hz/60Hz
Channel scanner / protective relay with data logger 85XX +
- Universal input for each Analog Input
- IP65 for Weather proof protection
- Easy Programming by front Touch sense keypad
- Fast Sampling rate with instantaneous relay action
- Four relays for alarm/trip
- RS485 Serial communication port for remote monitoring
- Multiple Levels of configuration and password protection
- Comprehensive Alarm/Trip logic programming
- Re transmission output (Optional)
Channel Logger / DAQ Module 8040
- 16 – 128 channel configuration
- Scans 128 channels in 3 seconds
- Two user dedicated serial communication Ports + one OT/HMI port
- Ethernet port / USB port (optional)
- 2 x 16 character LCD Operator display terminal
- Universal input for each channel
- Channel to channel input isolation option
- Battery backed memory with RTC
- Periodic Memory (25 MB)
- Host computer/ operator terminal programmable
- Pre Fab cable with DIN terminal Modules as accessories
- Field to Logic Isolation on Input cards
HT16u Intelligent Humidity Temperature Logger
- Compact RH/T Smart Logger with integral LCD display
- Max / Min readings with reset
- Logs up to 400,000 records with time stamp
- Hi/Lo Alarms status
- Selection of Temperature Unit Measurement in Celsius or Fahrenheit
- USB Port for Configuration, logged data retrieval and Aux Power
- Long Battery Life with status indication
- Operation by front keys
- SMART-HT software allows configuration and viewing of logged data
- Optional License to export the data in a report file
PI-TDS210-C Conductivity Meter
Features
- Range: 0.01 electrode: 0.02~20.00us/cm
- 0.1 electrode: 0.2~200.0us/cm
- 1.0 electrode: 2~2000us/cm
- 10.0 electrode: 0.02~20ms/cm
- Output signal: 4 ~ 20 mA; Relay; RS485
- Power supply: AC220V±10%, 50Hz/60Hz
- Operating temperature: 0~60°C
- Accuracy : ± 2 % PE
- Measuring medium: Liquid
- Relay output: 250 VAC, 3A
PI-DM2800 Membrane dissolved oxygen meter
- Range: 0-20 mg/L, 0-200%, 0-400 hPa
- Resolution: 0.01 mg/L, 0.1%, 1 hPa
- Output signal: 4 ~ 20 mA; Relay; RS485
- Power supply: AC220V±10%; 50Hz/60Hz
- Communication protocol: MODBUS-RTU standard (customizable)
- Operating temperature: 0~60 °C